Initial setting4 menu, Own ship information menu – Furuno FR-2115/2125 User Manual

Page 39

Advertising
background image

3-7

ECHO AVG W/O GYRO: Echo averaging can be turned on without gyrocompass
connection.

HEAD UP TB SCALE: Bearing scale may be shown in degrees or compass
points in the head-up mode.

CTR ECHO STRETCH: Turn on to enlarge echoes in the range up to the first
range ring.

VIDEO CONTRAST: For factory use. Do not change setting.

MAXIMUM RANGE: For factory use. Do not change setting.

ECHO FULL COLOR: Echoes may be displayed in one color or multi-color. Se-
lect ON for multi-color display.

INDEX LINES: Selects the number of index lines to display; 2, 3, or 6.

INITIAL SETTING4 menu

Keying sequence: [RADAR MENU] [0] [0] [0] [2] [0] [0] [0]

MODEL: Selects radar model.

TYPE: Selects specification of radar. Select R for R type; G for IMO type N for
Netherland type, W for Washington ferry.

CTR STC CURVE: Selects level of STC affect; Low, Medium or High.

RJ-7, RJ-8: Selects which Interswitch unit to use.

SHIP'S TYPE: Select class of vessel; deep sea, fishing, long line fishing.

CABLE LENGTH: Set for "500."

FACTORY DEFAULT: Restores all menus' default settings.

OWN SHIP INFORMATION menu

Keying sequence: [RADAR MENU] [0] [0] [0] [2] [6]

SHIP'S LENGTH: Enter ship's length.

SHIP'S WIDTH: Enter ship's width.

RADAR POSN: Enter distance from both bow and port to the radar antenna
location.

NAV ANT POSN: Enter distance from both bow and port to the navigation an-
tenna location.

TURN RATE: Enter ship's turn rate.

SPEED RATE: Enter ship's speed rate.