2 display unit, Fabricating the ac power cable (supplied), A) (b) (d) – Furuno FR-2115/2125 User Manual

Page 26: Dpycy-3.5

Advertising
background image

2-6

2.2 Display Unit

Two cables are terminated at the display unit: the signal cable S03-74 or S03-75
and the power cable. The signal cable comes with a connector preattached to it for
connection to the display unit. Fabricate the power cable as below.

Fabricating the AC power cable (supplied)

1. Remove the vinyl sheath by 80 mm.

2. Cut off jute tape wrapped around the armor.

3. Unravel the armor to expose the cores by about 35 mm.

4. Remove insulation of cores by about 10 mm. Fix crimp-on lugs to the cores and

armor.

5. Cover the armor with vinyl tape, leaving the portion which will lie inside the

cable clamp untaped.

40 mm

Clamp here.

Taping

(a)

(b)

(d)

Vinyl sheath

5 mm

Armor

DPYCY-3.5

10 mm

(c)

Approx. 80 mm

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,

,,,

,,,

,,,

,,,

,,,

Core
S = 3.5 mm

φ

= 2.4 mm

2

Armor

Vinyl sheath

(sectional view)

Figure 2-10 Fabricating power cable DPYCY-3.5

Advertising