Connect ductwork, Step 6, connect electrical, Caution – GE Monogram ZV755 User Manual

Page 12: Warning

Advertising
background image

12

Installation Instructions

INSTALLATION – VENTED TO THE OUTSIDE

CONNECT DUCTWORK

Remove shipping tape from the damper.
Install ductwork, making connections

in the direction of airflow as illustrated.

Push duct over the exhaust outlet and damper.

CAUTION:

Do not use sheet metal

screws at the exhaust outlet connection. Doing

so will prevent proper damper operation. Seal

connection with tape only.

Secure joints in ductwork with sheet metal screws.
Wrap all duct joints and the flange connections

with aluminized duct tape for an airtight seal.

5

Duct tape over

seam and

screw

Screw

Airflow

CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING:

If house wiring is not 2-wire

with a ground wire, a ground must be provided

by the installer. When house wiring is aluminum,

be sure to use U.L.-approved antioxidant compound

and aluminum-to-copper connectors.

Remove the junction box cover and the selected

knockout.

Secure the house wiring to the junction box with

a strain relief (not provided).

Connect the white lead to the branch circuit white lead.
Connect the black lead to the branch circuit black lead.
Connect the green/yellow lead to the branch

circuit green lead or bare ground lead.

Secure all the connections with wire nuts on each

electrical connector.

Push the wires into the junction box and replace

the cover. Be sure the wires are not pinched.

Secure the junction box cover with the 2 original

screws.

6

Junction

box cover

Knockout

Advertising