Installation instructions, Installation, Non recessed installation – Stovax E-Studio PR0776 User Manual

Page 17

Advertising
background image

17

1

AR1435

B

A

5.2 Gas pipe entry must come through the rear right-hand side

of the box. The rubber seal must be cut using a sharp knife

to allow the isolating elbow to pass through it.

• Ensure the rubber is not damaged when doing this,

Diagram 1, arrow B.

A means of isolation is provided with the appliance. This

must be fitted to the supply pipe prior to installing the

firebox.

The appliance can either be recessed into an inner leaf of

the wall. A 75mm rebate surround must be used with this

method. Or it can be installed in front of the wall in

conjunction with a fire surround constructed of a studwork

frame, Diagram 2 for options.

2

AR1428

AR1429

6. NON RECESSED INSTAllATION

6.1 • Mark the position of the flue on the inner wall by

measuring from the top of the finished hearth level,

Diagram 3.

INSTAllATION INSTRUCTIONS

INSTAllATION

3

AR1436

6.2 A 152mm (6’) diameter hole is required to install the flue.

This can be achieved by either:

a) Core drill

b) Hammer and chisel.

It is advisable to drill small holes around the circumference

when using method b. Make good both ends of the hole.

6.3 It will now be necessary to construct a studwork frame to

house the appliance. The minimum depth of the aperture

must be 237mm. This includes an air gap of 5mm behind

the appliance. The sides must be lined with non-

combustible material for the full depth of the aperture.

6.4 Combustible parts of the studwork frame must not be any

closer than the minimum dimensions shown in Diagram 4.

These dimensions need to be maintained even if the frame

work is protected by non combustible material.

6.5 Do not pack the void around or above the appliance with

insulation material such as mineral wool.

4

AR1430

AR1431

Advertising