5. ElECTRODE

5.1 • Pull the ignition lead from the electrode and undo the

retaining nut, Diagram 12

12

AR1349

• Replace with new electrode. Do not over tighten the nut

as this could break the new component

• Replace the ignition lead

6. ThERMOCOUPlE

6.1 • Disconnect the thermocouple from the gas valve,

Diagram 13

13

AR1434

A

• Undo the thermocouple nut in the pilot unit by half a

turn. This will release the thermocouple.

For E-Studio

6.2 • Remove the sealing plate, Diagram 14, by removing the

pozi head screw.

NOTE: The sealing plate needs to be re-sealed after the

new thermocouple is fitted.

4A. PIlOT INjECTOR - E-STUDIO

4.1 • Undo the pilot pipe from the bulkhead fitting and from

the underside of the pilot unit, Diagram 10

5

AR2002

10

• Remove the pipe and the injector drops out from the

pilot unit. Take care not to loose or damage the injector.

4.2 To replace the injector:

• Reverse the above procedure

• Check for gas leaks.

4B. PIlOT INjECTOR - E-BOX

4.3 • Undo the pilot pipe from the valve and from the under

side of the pilot unit, Diagram 11

11

AR1434

• Remove the pipe and the injector drops out from the

pilot unit. Take care not to loose or damage the injector.

4.4 To replace the injector:

• Reverse the above procedure

• Check for gas leaks