11. COMMISSIONING

11.1

Check all ceramics, doors etc.

11.2

Check flame picture

11.3

Check gas pressure

10. lIGhTING ThE APPlIANCE

10.1 • Locate the control valve on the fire. There are two

control knobs on the valve, the right-hand knob controls the

pilot ignition and the left hand knob controls the main

burner.

10.2 If your fire has already been upgraded to battery remote

control, please refer to the instructions provided with the

upgrade to operate the remote control. The

following instructions will work for either situation.

2

AR0914

• Ensure that the left-hand control knob is pointing to off (

).

• Ensure that the right hand control knob is pointing to

off ( ).

• Press in the right hand control knob and rotate it anti-

clockwise until a click is heard (keep pressing in) and the

knob is pointing to pilot

. The pilot should now light. If

the pilot has not lit,

repeat the procedure until it

does.

• Keep the control knob pressed for 10 seconds and then

release it, the pilot should stay alight. If the pilot goes out,

repeat the procedures until it does.

• Turn the right-hand control to point to main burner

.

The fire can now be controlled using the left-hand

control knob.

• Turn the left hand control knob to point to low fire

,

the main burner will light on low. The burner can

now be controlled between low and high settings. Turn the

control knob anticlockwise increase the flame height and

clockwise to decrease the flame height.


ThE YEllOw FlAMES wIll APPEAR whEN ThE FIRE

hAS GAINED SUFFICIENT hEAT - TYPICAllY 10 TO 20

MINUTES.