Servicing instructions, Replacing parts, Pilot unit – Stovax E-Studio PR0776 User Manual

Page 27: 2b. e-box

Advertising
background image

27

• Remove the ceramic coals and fuel bed and place on a

dry clean surface

• Remove the ceramic panels from inside the appliance

• Remove the two screws securing the front U channel on

the burner assembly. This is to gain access to the burner

retaining screws, Diagram 8.

8

AR1432

2.14 • Remove the 11 screws in the burner tray securing the

burner assembly to the appliance. The burner assembly can

now be removed by lifting it up and out of the appliance,

Diagram 9.

9

AR1433

3. PIlOT UNIT

The pilot unit assembly consists of three components which

can be individually changed, these are:-

1) Pilot Injector

2) Electrode

3) Thermocouple

Note: On the E-Box, access is provided for the removal of the

pilot without removing the engine assembly. It is easier,

however, to change the pilot by removing the whole

assembly.

5

AR2001

5

• Remove the 11 screws that fix the burner assembly into

the appliance, Diagram 6. The burner assembly can now

be removed by lifting it up and out of the appliance.

5

AR1980

6

2B. E-BOX

• Remove the glass window by loosening the four screws in

the lower retaining bracket then remove the four top screws

and retaining bracket. The glass window can now be lifted

clear, Diagram 7

AR1423

7

AR1465

SERvICING INSTRUCTIONS

REPlACING PARTS

Advertising