Example- Multiple Move Sequence

The AM trip point is used to separate the two PR moves. If AM is not used, the controller returns a ?
for the second PR command because a new PR cannot be given until motion is complete.

Instruction Interpretation

#TWOMOVE Label
PR 2000

Position Command

BGA Begin

Motion

AMA

Wait for Motion Complete

PR 4000

Next Position Move

BGA

Begin 2nd move

EN End

program

Example- Set Output after Distance

Set output bit 1 after a distance of 1000 counts from the start of the move. The accuracy of the trip
point is the speed multiplied by the sample period.

Instruction Interpretation

#SETBIT Label
SP 10000

Speed is 10000

PA 20000

Specify Absolute position

BGA Begin

motion

AD 1000

Wait until 1000 counts

SB1

Set output bit 1

EN End

program

Example- Repetitive Position Trigger

To set the output bit every 10000 counts during a move, the AR is used as shown in the next example.

Instruction Interpretation

#TRIP Label
JG 50000

Specify Jog Speed

BGA;n=0 Begin

Motion

#REPEAT

# Repeat Loop

AR 10000

Wait 10000 counts

TPA Tell

Position

SB1

Set output 1

WT50

Wait 50 msec

CB1

Clear output 1

n=n+1 Increment

counter

JP #REPEAT,n<5

Repeat 5 times

STA Stop
EN End

Example - Start Motion on Input

This example waits for input 1 to go low and then starts motion.