A

B

D

(a)

(b)

(c)

time

C

Figure A-23 - Vector and Axes Velocities

Example- Communicating with OPTO-22 SNAP-B3000-
ENET

Controller is connected to OPTO-22 via handle F. The OPTO-22’s IP address is 131.29.50.30. The
Rack has the following configuration:

Digital

Inputs

Module

1

Digital

Outputs

Module

2

Analog Outputs (+/-10V) Module 3

Analog Inputs (+/-10V) Module 4

Instruction Interpretation

#CONFIG Label
IHF=131,29,50,30<502>2 Establish connection
WT10

Wait 10 milliseconds

JP #CFGERR,_IHF2=0

Jump to subroutine

JS #CFGDOUT

Configure digital outputs

JS #CFGAOUT

Configure analog outputs

JS #CFGAIN

Configure analog inputs

MBF = 6,6,1025,1

Save configuration to OPTO-22