Installation instructions, Site requirements – Stovax F40 User Manual

Page 10

Advertising
background image

1.1

The chimney or flue system must comply with the rules in

force, and must be a minimum of 127mm in diameter. (5").

1.2

The minimum effective height of the flue or chimney must

be 3 metres (10ft). Any horizontal flue run from the rear

outlet should not exceed 100mm from the back of the

appliance.

1.3

The chimney or flue must be free from any obstruction. Any

damper plates should be removed or secured in the fully

open position, and no restrictor plates should be fitted.

1.4

The chimney should be swept prior to the installation of the

appliance. However, where it can be seen that the chimney

is clean and unobstructed throughout its entire length, it

need not be swept.
NOTE: If it is intended to fit the stove into a existing brick

built chimney a 5" (127mm) liner must be used. Larger lined

flues may work, but in some instances could cause cold

start flue problems resulting in nuisance shutdown. Lined

flues above 7" (175mm) are not recommended.
Due to recent changes to European chimney standards,

new flue’s and chimney’s are now described by their

temperature, pressure and resistance to corrosion,

condensation and fire. To assist in identifying the correct

flue system, the minimum flue specification is shown in the

technical specification on page 8 of this book. Existing

chimney’s are not covered by this system.

2.1

Consult the rules in force.

Note: This appliance does not normally require any

additional ventilation when installed in G.B.

3.1

Before installation, ensure that the local distribution

conditions (identification of the type of gas and pressure)

and the adjustment of the appliance are compatible.

3.2

Ensure that the gas supply is capable of delivering the

required amount of gas, and is in accordance with the rules

in force.

3.3

Soft copper tubing and soft soldered joints can be used but

must not be closer than 50mm to the base of the tray.

3.4

A means of isolating the gas supply to the appliance must

be provided independent of any appliance control.

3.5

All supply gas pipes must be purged of any debris that may

have entered, prior to connection to the appliance.

4.1

This fire must stand on a non-combustible hearth that is at

least 12mm thick and projects 50mm minimum from the

base of the fire in all directions.

4.2

Do not install in a room that contains a bath or shower.

MINIMUM CLEARANCE

4.3

The fire is not suitable for installation against a combustible

wall. All combustible materials must be removed from

behind the fire.

4.4

Ensure you comply with all minimum clearance

measurements, whether or not to combustible materials.

See diagram 2 & 2A.

The above dimensions provide adequate clearance at the

side and rear of the fire so that controls can be reached.

4. APPLIANCE LOCATION

3. INSTALLATION OF THE GAS SUPPY

2. VENTILATION

1. FLUE AND CHIMNEY REQUIREMENTS

10

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

1

A = 562mm

B = 431mm

C = 12mm

AR1468

AR1469

50

2

3