Servicing instructions, Replacing parts – Stovax F40 User Manual

Page 20

Advertising
background image

10.1 Open and remove the front door. Remove the glass frame.

Carefully remove the ceramic components and place to one

side. Undo the two screws at the back of the firebox and

carefully withdraw the bracket. See diagram 16

10.2 Disconnect the two sender wires. Undo the two taptite

screws and remove the sensor and the two plastic spacers.

See diagram 17

10.3 Refit the new sensor ensuring that the plastic spacers are

between the sensor and the bracket. Refit the leads. See

diagram 18

10.4 Feed the cable back through the hole as you replace the

bracket. When the bracket is located correctly it will sit

flush with the back panel without force required. If not

positioned correctly the bracket will sit at an angle. See

diagram 19

In order to change between gas types, it will be necessary

to change the following items

Pilot Unit

Control Valve**

Main Injector

Aeration Plate

Control Unit

Data Badge

The relevant parts can be ordered from Gazco, always

quote the appliance type and serial number when ordering

spare parts.

**NOTE: THE CONTROL VALVE IS FACTORY PRESET

FOR CORRECT GAS TYPE AND MODEL, A NEW UNIT

WILL NEED TO BE ORDERED WHEN CHANGING

BETWEEN GAS TYPES.

10. GAZCO FLUE SURE SYSTEM

20

SERVICING INSTRUCTIONS

REPLACING PARTS

16

17

11. CHANGING BETWEEN GAS TYPES

AR1442

AR1446

18

AR1452

AR1448

AR1447

19

Advertising