User instructions, 2 to adjust the flame height, 3 to turn the f40 avanti off – Stovax F40 User Manual

Page 5: 4 to change from manual to automatic mode, 5 to set the room temperature, 6 to change from automatic to manual mode, 7 low battery display (hand set), 8 lighting the f40 avanti (touch pad), 9 to adjust the flame height (touch pad)

Advertising
background image

IF THE FIRE IS EXTINGUISHED OR GOES OUT IN USE,

WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT

THE FIRE. THE CONTROL VALVE HAS AN INTERLOCK

DEVICE AND THEREFORE CANNOT BE LIT UNTIL THE 3

MINUTES HAVE ELAPSED.

2.2 To adjust the flame height

Once the pilot has been lit the main burner can be lit and

adjusted.

2.2.1 Press the (

) UP button (10). The flame symbol (1) will

show one extra flame. This is to indicate the burner is on its

lowest position.

2.2.2 Press the same button again and the burner will be in the

medium position.

2.2.3 Press the button again and the burner will be in the

maximum position.

2.2.4 Press the (

) DOWN button (13) one step at a time and

this will reduce the burner from maximum to medium then

to minimum.

2.2.5 If the (

) DOWN button is pressed once more, only the

pilot will remain alight.

2.3 To turn the F40 Avanti off

The F40 Avanti can be turned off with the flames in any

position, ie minimum, medium or maximum. It can also be

turned off from the pilot only position.

2.3.1 Press the ON / OFF button (11) the word OFF appears in

the display.

2.3.2 Press the SET button (12) and the fire will turn off.

NOTE:

The pilot can be left on if so desired

2.4 To change from Manual to Automatic mode

2.4.1 The hand set display will show the word MANUAL (8)

2.4.2 Press the SET button (12) once and the word AUTO will

flash.

2.4.3 Press the SET button (12) again and the word AUTO will

stop flashing.

2.4.4 The room temperature display is now flashing and ready to

be set.

2.5 To set the room temperature

2.5.1 Following on from section 2.4, once the room temperature

is flashing on the display, it can be set.

2.5.2 Press either the (

) button (10) or the (

) button (13) to

either increase or decrease the temperature.

2.5.3 Press the SET button (12) once you have set the

temperature as desired.

If the SET button (12) is not pushed the temperature display

will stop flashing and remain unchanged.

2.6 To change from Automatic to Manual

mode.

2.6.1 The hand set display will show AUTO (8).

2.6.2 Press the SET button (12) once and the word MANUAL will

flash.

2.6.3 Press the SET button (12) again and the word

MANUAL will stop flashing.

You are now in Manual mode.

2.7 Low battery display (Hand Set)

The low battery symbol (6) will appear on the hand set

when the batteries require replacement.

2.8 Lighting the F40 Avanti (Touch Pad)

2.8.1 The touch pad is located behind the main door. To open

the door, press the lower right hand corner of the door until

a click is heard, open the door and the touch pad can be

seen. See diagram 3.

2.8.2 Press the ON / OFF button (A) once and the red LED will

flash. The pilot will now light. This should take about 10

seconds. If the pilot does not light press the ON / OFF

button again to reset the control unit and repeat step 1

above. Before the burner can be lit wait for the audible

click. See diagram 4.

2.9 To adjust the flame height (Touch Pad)

2.9.1 Once the pilot has lit press the Up (

) button (B) and the

burner will light. See diagram 4.

2.9.2 Press either of the (

) buttons (B / C) to adjust the

height of the flames. See diagram 4.

5

USER INSTRUCTIONS

3

AR1466

Advertising