Servicing instructions, Commissioning – Stovax F40 User Manual

Page 14

Advertising
background image

4.2

Close the door by pushing the lower right corner of the

door until a click is heard. The door will now have latched.

Opening is done by the lower right hand door, again until a

click is heard, and opening to its stop.

NOTE: THE HANDSET HAS BEEN FACTORY

PROGRAMMED TO OPERATE THIS APPLIANCE. IF THE

HANDSET OR CONTROL UNIT HAS BEEN REPLACED, IT

WILL BE NECESSARY TO FOLLOW THE PROGRAMMING

PROCEDURE.
PROGRAMMING THE HANDSET
Section 5 must be read in total before trying to programme

the handset! The sequence must be performed while the

ON/OFF on the display is still flashing.

5.1

Open the lower door by pressing until a ‘click’ is heard.

Now switch the button on the control unit to the Unlock

position . See diagram 18.

5.2

The remote handset must now be programmed. Push the ON /

OFF button (11), the ON or OFF display will start flashing. Then

press the ON / OFF button (11), and the (

) (10) and (

)

(13) buttons at the same time.

Immediately after press the SET button (12) once. See diagram

19.

5.3

The clock (7) will appear on the display. After a few seconds this

will disappear.

5.4

Finally push the switch to the Lock position , towards the rear

of the appliance. The remote should now be tuned to the

control box.

5.5

Close the lower door untill a ‘click’ is heard.

5.6

Close all openable doors and windows in the room, ignite the

appliance and operate on maximum for 10 minutes. Remove

the plastic sight plug from the right hand side of the appliance.

Position a lighted smoke match just inside the draught diverter

opening and check that all smoke is drawn into the opening by

viewing through the sight hole. See diagram 20. If there is any

doubt, run the appliance for a further 10 minutes, and repeat

the test.

5.7

If there are any extractor fans in adjacent rooms, the test must

be repeated with the fans running on maximum and

interconnecting doors open.

IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE

AND SEEK EXPERT ADVICE.

For future reference record the installation details on

commissionging sheet page 3 of these instructions.

5. COMMISSIONING

14

SERVICING INSTRUCTIONS

COMMISSIONING

18

20

AR1493

19

1: Flame display
2: Celsius display
3: Temperature display
4: On display
5: Off display
6: Low battery display
7: Clock display
8: Auto display
9: Manual display
10: UP button
11: ON/OFF button
12: SET button
13: DOWN button

AR1665

1

2

3

10

11

5

6

7

4

8

9

12
13

AR1676

Advertising