Installation instructions, Installation – Stovax F40 User Manual

Page 12

Advertising
background image

2.6 Remove the four black screws in the firebox and lift the

firebox clear. See diagram 5.

2.7 For Midi and Highline versions of the F40, it will be

necessary to remove the base panel. This lifts up and

through the upper part of the carcass. See diagram 6.

2.8

It will now be possible to access the two tabs for bolting the

appliance down (if required). Position the stove ensuring all

appropriate clearances are observed. Using a pencil mark

the position of the holes in the fixing bracket. See diagram

7.

2.9

Remove the stove and drill the holes using a masonary drill.

Insert the rawlplugs.

2.10 Reposition the stove and level it using the three levelling

bolts in the base. Screw the stove down. Replace the

decorative base cover panel if fitted.

2.11 Refit the fire box and burner unit to the stove taking care to

reconnect the small TTB electrical connector to the left

hand terminal and the large TTB connector to the right

hand terminal. See diagram 8.

2.12 THE TTB CONNECTIONS IN THE INTERUPTOR BLOCK

MUST HAVE THE RED HIGHLIGHTED SPADE CLOSEST

THE VALVE. SEE DIAGRAM 9.

2.13 Having run the gas supply to the stove, PURGE THE

SUPPLY, this is essential to expel any debris that may block

the controls. Connect the gas supply to the 8mm test point

located at the lower right hand side of the stove. A gas

soundness check must be completed up to the gas inlet

connection. See diagram 10.

2.14 Check the pull of the flue system by applying a lighted

smoke pellet to the flue system opening. If there is a

definite flow into the chimney, proceed with the

installation, if not warm the chimney for a few minutes.

12

INSTALLATION INSTRUCTIONS

INSTALLATION

8

9

AR1472

AR1362

7

AR1456

6

AR1471

5

AR1470

10

AR1461

Advertising