1.1 Installation and servicing must be carried out by a

competent person in accordance with Gas Safety

(Installation and Use) Regulations 1998, the relevant British

Standards for Installation, appropriate Codes of Practice and

in accordance with the manufacturers instructions. It is

recommended that a CORGI registered engineer be used

for this purpose as they are approved by the HSE under the

above regulations.

1.2

This appliance is suitable for use in G.B. and I.E. using

Natural Gas at a supply pressure of 20mbar or LPG at a

supply pressure of 28mbar (Butane) or 37mbar (propane).

1.3

The installation shall also be completed in accordance with:

The Building Regulations issued by The Department of The

Environment.

The Building Standards (Scotland) Regulations issued by the

Scottish Development Department.

For Republic of Ireland, reference should be made to the

relevant standards governing installations (IS813:1996)

1.4

Read all these instructions before commencing installation.

1.5

This appliance must be installed in accordance with the

rules in force and only used in a sufficiently ventilated

space.

1.6

Ensure that curtains are not positioned above the stove, and

that there is at least a clearance of 300mm between the

sides of the stove and any curtains.

1.7

The manufacturer considers the full outer casing of this

stove to be a working surface. Therefore it will become hot

whilst in operation. A suitable guard is recommended to

protect young children, the aged and the infirm.

1.8

This stove must only be operated with the door secured

firmly in position. If any cracks appear in the glass the

appliance must not be used until the glass panel is replaced.

1.9

Do not attempt to burn rubbish in this stove.

1.10 Any combustible shelves or surrounding furniture must only

be fitted in accordance with the minimum dimensions

detailed in diagram 1.

1.11 Contact a competent service engineer to carry out relevant

spillage checks etc. following home improvements carried

out after installation of this stove (e.g. the fitting of double

glazing).

1.12 In all correspondence, please quote the appliance type and

serial number which can be found on the databadge at the

rear of the stove.

1.13 This product is guaranteed for 2 years from the date of

installation, as set out in the terms and conditions of sale

between Gazco and your local Gazco dealer. Please consult

with your local Gazco dealer if you have any questions. In

all correspondence always quote the model No. and serial

No. Please ensure the commissioning checklist is

completed by your installer, as this is a requirement of

your Guarantee.

2.1

To ignite the F40 Avanti

The Gazco F40 Avanti has a fully automatic battery

operated gas control which can be lit using the hand set or

touch pad. The touch pad is located on the lower front

panel of the appliance, behind the main door.

2.1.1 Before the fire can be lit the remote control must be in the

manual mode. See diagram 2. Refer to section 2.6 to

change to manual mode.

2.1.2 Press the ON / OFF button (11). The word ON appears in

the display (4).

2.1.3 Press the SET button (12). The pilot light should now light.

This should take about 10 seconds.

If the pilot fails to light press the ON / OFF button (11) and

then the SET button (12) then repeat the above sequence.

2.1.4 A single flame will appear on the display (1). When this has

stopped flashing, an audible click is heard. You are now

ready to adjust the flame height.

2. LIGHTING THE F40 AVANTI

WITH HAND SET

1. GENERAL

4

USER INSTRUCTIONS

1

AR1468

2

1: Flame display
2: Celsius display
3: Temperature display
4: On display
5: Off display
6: Low battery display
7: Clock display
8: Auto display
9: Manual display
10: UP button
11: ON/OFF button
12: SET button
13: DOWN button

AR1665

1

2

3

10

11

5

6

7

4

8

9

12

13

Advertising