Installation instructions, Technical specification, Packing checklist – Stovax F40 User Manual

Page 9

Advertising
background image

9

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

COVERING THE FOLLOWING MODELS

8685MCSC - P8685MCSC

8685MMCSC - P8685MMCSC

8685HMCSC - P8685HMCSC

MODEL

GAS

GAS

WORKING

NOX

AERATION

INJECTOR

GAS RATE

INPUT kW (Gross)

COUNTRY

TYPE

PRESSURE CLASS

m

3

/h

High Low

F40 Avanti

I

2H

NG

20 mbar

5

1x7.5mm

1.7

0.515

5.4 3.5

GB, IE

8685

G20

F40 Avanti

I

3P

LPG Propane

37 mbar

5

1x13.5mm

1.2

0.201

5.5 3.5

GB, IE

P8685

G31

Efficiency Class II

Flue Outlet Size 127mm (5”) ø

Gas Inlet Connection Size 8mm ø

Miminum flue specification

T260 / N2 / O / D / 1

Maximum flue temperature

180°c

PACKING CHECKLIST

QTY

Description

1

Stove

1

Flue infill plate

1

Front coal

1

Coal set

1

Rear Ceramic

1

Fixing kit containing:-

1

Instruction manual

2

Wood screws

2

Rawl plugs

1

Remote handset

3

‘C’ cell batteries

3

‘AAA’ cell batteries

AR1450

Advertising