3.3

Remove the lint arrestor by folding the tabs back. See

diagram 6.

3.4 Undo the compression nut on the pilot unit, disconnect the

ignition lead from the electrode by pulling gently down on

the wire. Undo the two screws and the pilot unit can be

removed. See diagram 7

3.5 Reassemble in reverse order, check for gas leaks.

4.1 Follow steps 2.1 to 2.5 to remove the burner unit, making

sure that the gas supply is isolated at the isolation point.

4.2 Cut the cable tie, gently pull the lead out from the

electrode and the control unit.

4.3 Reassemble in reverse order, check for gas leaks. Take care

not to route the ignition lead too close to other electrical

leads.

5.1 Follow steps 2.1 to 2.5 above to remove the burner unit,

making sure the gas supply is isolated at the isolation point.

Turn the burner unit over, the aeration plate is accessible

from below.

5.2 Undo the M5 nyloc nut, and remove the aeration plate. See

diagram 8

5.3 Reassemble in reverse order with the correct aeration plate.

Check for gas leaks.

6.1

Follow steps 2.1 to 2.5 above, making sure the gas supply is

isolated at the isolation point. Turn the burner unit over and

disconnect the thermocouple lead. See diagram 9

6.2 Disconnect the TTB leads and unscrew the interrupter block

(A). Support the valve and undo the magnetic valve

retaining nut (B). See diagram 10

6.3 Remove the magnetic valve unit located inside. Reassemble

in reverse order, taking care to assemble the TTB leads with

the red highlighted one closest the valve. Check for gas

leaks.

6. MAGNETIC SAFETY VALVE