Iring, Iagram, Warning – Goodman Mfg SS-CPG36-72 User Manual

Page 39: Roduct, Pecifications, Hree, Hase, Irect, Rive, C2 2

Advertising
background image

38

www.goodmanmfg.com

SS-CPG36-72

SS-CPG36-72

www.goodmanmfg.com

39

P

roduct

S

PecificationS

P

roduct

S

PecificationS

Wiring is subject t

o chang

e. Alw

ay

s

re

fer

to the wiring diagr

am or the

unit

for the mos

t up-t

o-da

te

wiring.

W

arning

High

Volt

ag

e:

Disc

onn

ect

all

po

w

er

be

for

e

ser

vicing

or

in

st

alling

this

unit.

Multiple

po

w

er

sour

ces

ma

y

be

pr

esen

t.

Failur

e

to

do

so

ma

y

cause

pr

operty

damag

e,

per

sonal

injur

y,

or

dea

th.

w

irinG

d

iaGram

CPG036/48*3d (t

hree

-P

hase

, d

ireCt

d

rive

)

C

RD

WH

YL

RD

RD

11

8

12

9

7

10

4

2

5
6

3

1

FS

RD

BK

SEE NOTE 8
GREEN JUMPER

COOL

DI

L1

HEA
T

UN

USE
D

L2

BL

BK

YL

YL

PU

BR

BL

RD

PU

WH

GR

BL

P1

RD

GR

PS

RS

PLF

YL

YL

NOTE 4

GAS VALVE

MV

2

1

4

5

YL

BL

W. R.

GAS VALVE

PU

(ALT.) HONEYWELL

3

6

YL

BR

PU

PU

BK

BR

R

G

Y1 W 1

OR

RD

TO THERMOSTAT

C

MV

FS

IGN

VM

BL

RD

BL

BK

GV

GV

TB1

PU

BL

YL

GR

Y2

YL

RD

RD

BL

BL/PK

YL/PK

HPS

LPS

RD

BK

SEE
NOTE 9

F

W2

BR

FC

WH

RD

GND

YL

208-240/3/60
SEE NOTE 5

RD

YL

RD

BR

EA

KF

OR

TWO
STA

GE

T2

CO

MP

RE

SS

OR

IIC

RD

L2

C

T2

L1

T1

RD

BK

BK

PU

YL

C2

2

OR

SP

EE

D-U

P

MO

UNT

T1

P2

REQUIR

ED

SC

RE

W

P3

13

5

12

0

15

0

FU

SE

3AM

PM

AX

F1

EC

ON

ALS

PU

3

2

1

RD

RD

LS

208

TR

BL

24V

C

PK

240

BL

NOTE 2

PU

BK

BR

S1

PK

TB1

S2

FOR
SMOKE/FIRE
DETECTOR
REPLACE
JUMPER

BL

BL

GR

BK

BR

RD

PU

EM

BL

3 SPEED

PU

PU

BR

CM

BK

ALTERNATE
MOTOR
6-WIRES
SEE NOTE 6 & 7

BC

BC

3 SPEED

BL

EM

RD

BK

BR

RD

PU

COMP

T1

T2

T3

SEE NOTE 7

RD

L2

T2

L3

T3

POW ERSUPPLY

BK

208-240/3/60

0140L00507

REV B

2. FOR 208 VOLT TRANSFORMER OPERATION

MOVE BLACK WIRE FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.

1. REPLACEMENT WIRE MUST BE THE SAME

SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).

AUXILIARY LIMIT SWITCH

FEMALE PLUG/CONNECTOR

INTEGRATED IGNITION CONTROL

LS

4

INSTALLER/SERVICEMAN

TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO

STATUS LIGHT

3 BLINKS

6 BLINKS

2 BLINKS

4 BLINKS

5 BLINKS

OFF

ON

1 BLINK

OPEN AUX. LIMIT

FALSE FLAME SENSED

OUTPUT DELAY

OPEN LIMIT SW ITCH

COMPRESSOR

WITHOUT INDUCER ON

PRESSURE SWITCH CLOSED

PRESSURE SW ITCH

SW ITCH

OPEN

OPEN ROLLOUT

SW ITCH

IGNITION FAILURE

NORMAL OPERATION

NO POWER OR

INTERNAL CONTROL

EQUIP. STATUS

OR

OR

FAULT

TO THERMOSTAT
TERMINAL BLOCK

G

R

5

7

9

ECON

IIC

Y1

W

Y2

3

6

12

10

8

11

RS

ALS

PS

BAD SW ITCH

AUX. LIMIT OPEN

ANTI-CYCLE TIMER

MAIN LIMIT OPEN

STICKING GAS VALVE

BAD SW ITCH

3 MIN. COMP.

PRESSURE SW ITCH

PRESSURE SW ITCH

CHECK

CHECK

GAS PRESSURE

FLAME ROLLOUT

FLAME SENSOR

GAS VALVE

CHECK FUSE ON CONTROL

CHECK INPUT POWER

REPLACE CONTROL

GAS FLOW

CHECK

-

PLF

C

NOTE
4

4

3

2

1

5

6

GV

C

L1

208-240/3/60

SUPPLY VOLTAGE

CM

CONDENSER MOTOR

L3

LS

LIMIT SWITCH

VENT MOTOR RELAY

VENT MOTOR

PRESSURE SWITCH

TERMINAL BLOCK (24V SIGNAL)

ROLLOUT SWITCH

VMR

VM

PS

PLF

TB1

RS

NOTES

FAN CAPACITOR

CONTACTOR

GAS VALVE

IGNITOR

EQUIPMENT GROUND

FLAME SENSOR

EVAPORATOR MOTOR

FC

FUSE

F

C

GV

FS
GND

IGN

IIC

EM

L2

L3

COMPRESSOR

COMPONENT LEGEND

COMP

ALS

TB1

TR

TRANSFORMER

L2

C

CM

T3

COMP

T3

T2

FC

L1

C

T1

T1

C

T2

208-240/3/60

0140L00507

REV B

HPS

LPS

LPS

LOW PRESSURE SWITCH

HPS

HIGH PRESSURE SWITCH

HIGH VOLTAGE

FACTORY WIRING

OPTIONAL
HIGH VOLTAGE

LOW VOLTAGE

FIELD WIRING

LINE VOLTAGE

LOW VOLTAGE

BL

RD

Y1

Y/Y2

YL

W

Y/Y2

BL

G

R

W

NO ECONOMIZER

G

YL

RD

Y/Y2

Y1

PK

WH

W

R

RD

WH

GR

C

R

YL

GR

Y1

G

WH

WITH ECONOMIZER OPTION

C

GR

THERMOSTAT
FIELD WIRING

BL

C

2 STAGE COOLING

TB1

G

R

W

Y

C

TB1

TB1

Y

W

R

G

C

W

Y2

G

R

C

Y1

STAT

STAT

STAT

BL/PK

BLUE WITH PINK STRIP

YL/PK

YELLOW WITH PINK STRIP

GR

GREEN

WIRE CODE

BL

BLUE

PU

PURPLE

PK

PINK

WH

WHITE

BK

BLACK

RD

RED

BR

BROWN

OR

ORANGE

YL

YELLOW

EM

DI

PCB

HEAT

COOL

FC

PCB

LI

TB1

IIC

FS

TR

FS

F

IGN

SEE NOTE 2

2

1

3

3. FOR DIFFERENT THAN FACTORY SPEED TAP.

CHANGE COOLING SPEED AT COOL
TERMINAL. CHANGE HEATING SPEED AT
HEAT TERMINAL ON CONTROL BOARD

BK - HIGH SPEED

BL - MED. SPEED

RD - LOW SPEED

3 SPEED MOTOR

4. ACCESSORY ECONOMIZER PLUG ADJACENT

TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND

ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.

USE NEC CLASS 2 WIRE.

5. USE COPPER CONDUCTORS ONLY.

7. SPEED TAP TERMINATIONS SHOWN ON

DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL
FACTORY SETTING MAY BE DIFFERENT BASED
ON HEATING VALUE AND CAPACITY OF UNIT.

6. PURPLE WIRE CONNECTS TO TRANSFORMER

(PIN 1).

8. TO RUN DIFFERENT SPEED FOR HEATING AND

COOLING, DISCONNECT GEEEN JUMPER FROM
"COOL" TERMINAL AND REPLACE WITH
APPROPRIATE SPEED TAP. THEN PLACE
DISCONNECTED END OF JUMPER ON
"UNUSED" TERMINAL LEFT OPEN BY MOVING

THE SPEED TAP.

9. FOR LOW STAGE OPERATION ONLY, REMOVE

WHITE JUMPER. FOR 2 STAGE OPERATION,
REMOVE JUMPER AND CONNECT W2 TO W1
ON THERMOSTAT.

BLOWER CAPACITOR

BC

SEE UNIT RATING PLATE FOR TYPE AND SIZE OF
OVERCURRENT PROTECTION.

VM