Iring, Iagram, Rive – Goodman Mfg SS-CPG36-72 User Manual

Page 40: Roduct, Pecifications, Arnin g

Advertising
background image

40

www.goodmanmfg.com

SS-CPG36-72

SS-CPG36-72

www.goodmanmfg.com

41

P

roduct

S

PecificationS

P

roduct

S

PecificationS

Wiring

is

subject

to

change.

Al

wa

ys

refer

to

the

wiring

diag

ram

or

the

unit

for

the

most

up-to-da

te

wiring

.

w

arnin

G

High

Voltage:

Disconnect

all

power

bef

or

e

ser

vicing

or

installing

this

unit.

Multiple

power

sour

ces

ma

y

be

pr

esent.

F

ailur

e

to

do

so

ma

y

cause

pr

operty

damage,

per

sonal

injur

y,

or

dea

th.

w

irinG

d

iaGram

— CPG036-600904B/7B — CPG036*4B/7B — CPG072*4B/7B (460v/575

v

, B

elt

d

rive

)

FS

IGN

BK

VM

OR

RD

FC

RD

BR

HPS

BL/PK

TO THERMOSTAT

SEE
NOTE 5

BR

GND

T3

RD

OR

L3

YL

BK

GR

YL

IIC

T1

T2

BK

PU

YL

BK

RD

C

L1

L2

BL

BL

RD

OR

BK

BK

T3 T2 T1

PU

COMP

CM

BR

BK

RD

RD

LS

W H

GR

10

7

9

12

8

11

ECON

BL
PU

RD

RD

RD

1

3

2

6

5

4

WH

L1

BR

FS

YL

RD

DI

BL

RD

YL

YL

BL

GR

YL

PU

YL

PU

PS

5

4

1

2

NOTE 2

PLF

6

3

YL

RS

ALS

GR

HEA
T

COOL

UN

US

ED

BL

BL

L2

BL

YL

MV

MV

PU

PU

W. R.

GAS VALVE

GV

BL

BL

(ALT.) HONEYW ELL

GAS VALVE

GV

GR

OR

RD

BK

OR

EM

RD

WH

2

1

3

VMR

BL

24V

TR

BL

BL

1

460

2

3

C

460/575

TR

240

BK

OR

PU

SEE
NOTE 3

BR

SMOKE/FIRE
DETECTOR
REPLACES JUMPER
W IRE

RD

TB1

PK

T2

T1

T3

C

BC

BK

RD

OR

LPS

L1

L2

L3

OR

BK

W H

OR

BL

S1

S2

YL/PK

GR

POWER SUPPLY

SEE NOTE 4

460/3/60

575/3/60

575

W2 G

Y

YL

Y1

C

BL

R

RD

W

WH

GR

SEE
NOTE 3

WH

BL

BR

OR

BK

460-575/3/60

0140L00870 REV B

2. FOR 208 VOLT TRANSFORMER OPERATION

MOVE BLACK WIRE FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.

1. REPLACEMENT WIRE MUST BE THE SAME

SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).

AUXILIARY LIMIT SWITCH

FEMALE PLUG/CONNECTOR

INTEGRATED IGNITION CONTROL

LS

4

INSTALLER/SERVICEMAN

TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO

STATUS LIGHT

3 BLINKS

6 BLINKS

2 BLINKS

4 BLINKS

5 BLINKS

OFF

ON

1 BLINK

OPEN AUX. LIMIT

FALSE FLAME SENSED

OUTPUT DELAY

OPEN LIMIT SW ITCH

COMPRESSOR

WITHOUT INDUCER ON

PRESSURE SWITCH CLOSED

PRESSURE SW ITCH

SW ITCH

OPEN

OPEN ROLLOUT

SW ITCH

IGNITION FAILURE

NORMAL OPERATION

NO POWER OR

INTERNAL CONTROL

EQUIP. STATUS

OR

OR

FAULT

TO THERMOSTAT
TERMINAL BLOCK

G

R

5

7

9

ECON

IIC

Y1

W

Y2

3

6

12

10

8

11

RS

ALS

PS

BAD SW ITCH

AUX. LIMIT OPEN

ANTI-CYCLE TIMER

MAIN LIMIT OPEN

STICKING GAS VALVE

BAD SW ITCH

3 MIN. COMP.

PRESSURE SW ITCH

PRESSURE SW ITCH

CHECK

CHECK

GAS PRESSURE

FLAME ROLLOUT

FLAME SENSOR

GAS VALVE

CHECK FUSE ON CONTROL

CHECK INPUT POWER

REPLACE CONTROL

GAS FLOW

CHECK

-

PLF

C

NOTE
4

4

3

2

1

5

6

GV

C

L1

208-240/3/60

SUPPLY VOLTAGE

CM

CONDENSER MOTOR

L3

LS

LIMIT SWITCH

VENT MOTOR RELAY

VENT MOTOR

PRESSURE SWITCH

TERMINAL BLOCK (24V SIGNAL)

ROLLOUT SWITCH

VMR

VM

PS

PLF

TB1

RS

NOTES

FAN CAPACITOR

CONTACTOR

GAS VALVE

IGNITOR

EQUIPMENT GROUND

FLAME SENSOR

EVAPORATOR MOTOR

FC

FUSE

F

C

GV

FS
GND

IGN

IIC

EM

L2

L3

COMPRESSOR

COMPONENT LEGEND

COMP

ALS

TB1

TR

TRANSFORMER

L2

C

CM

T3

COMP

T3

T2

FC

L1

C

T1

T1

C

T2

208-240/3/60

0140L00507

REV B

HPS

LPS

LPS

LOW PRESSURE SWITCH

HPS

HIGH PRESSURE SWITCH

HIGH VOLTAGE

FACTORY WIRING

OPTIONAL
HIGH VOLTAGE

LOW VOLTAGE

FIELD WIRING

LINE VOLTAGE

LOW VOLTAGE

BL

RD

Y1

Y/Y2

YL

W

Y/Y2

BL

G

R

W

NO ECONOMIZER

G

YL

RD

Y/Y2

Y1

PK

WH

W

R

RD

WH

GR

C

R

YL

GR

Y1

G

WH

WITH ECONOMIZER OPTION

C

GR

THERMOSTAT
FIELD WIRING

BL

C

2 STAGE COOLING

TB1

G

R

W

Y

C

TB1

TB1

Y

W

R

G

C

W

Y2

G

R

C

Y1

STAT

STAT

STAT

BL/PK

BLUE WITH PINK STRIP

YL/PK

YELLOW WITH PINK STRIP

GR

GREEN

WIRE CODE

BL

BLUE

PU

PURPLE

PK

PINK

WH

WHITE

BK

BLACK

RD

RED

BR

BROWN

OR

ORANGE

YL

YELLOW

EM

DI

PCB

HEAT

COOL

FC

PCB

LI

TB1

IIC

FS

TR

FS

F

IGN

SEE NOTE 2

2

1

3

3. FOR DIFFERENT THAN FACTORY SPEED TAP.

CHANGE COOLING SPEED AT COOL
TERMINAL. CHANGE HEATING SPEED AT
HEAT TERMINAL ON CONTROL BOARD

BK - HIGH SPEED

BL - MED. SPEED

RD - LOW SPEED

3 SPEED MOTOR

4. ACCESSORY ECONOMIZER PLUG ADJACENT

TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND

ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.

USE NEC CLASS 2 WIRE.

5. USE COPPER CONDUCTORS ONLY.

7. SPEED TAP TERMINATIONS SHOWN ON

DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL
FACTORY SETTING MAY BE DIFFERENT BASED
ON HEATING VALUE AND CAPACITY OF UNIT.

6. PURPLE WIRE CONNECTS TO TRANSFORMER

(PIN 1).

8. TO RUN DIFFERENT SPEED FOR HEATING AND

COOLING, DISCONNECT GEEEN JUMPER FROM
"COOL" TERMINAL AND REPLACE WITH
APPROPRIATE SPEED TAP. THEN PLACE
DISCONNECTED END OF JUMPER ON
"UNUSED" TERMINAL LEFT OPEN BY MOVING

THE SPEED TAP.

9. FOR LOW STAGE OPERATION ONLY, REMOVE

WHITE JUMPER. FOR 2 STAGE OPERATION,
REMOVE JUMPER AND CONNECT W2 TO W1
ON THERMOSTAT.

BLOWER CAPACITOR

BC

SEE UNIT RATING PLATE FOR TYPE AND SIZE OF
OVERCURRENT PROTECTION.

VM