Iring, Iagram, Rive – Goodman Mfg SS-CPG36-72 User Manual

Page 42: Roduct, Pecifications, Arnin g

Advertising
background image

42

www.goodmanmfg.com

SS-CPG36-72

SS-CPG36-72

www.goodmanmfg.com

43

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

irinG

d

iaGram

CPG036/480454B

CPG072*4B/7B (460v/ 575v B

elt

d

rive

)

Wiring

is

subject

to

change.

Al

wa

ys

refer

to

the

wiring

diag

ram

or

the

unit

for

the

most

up-to-da

te

wiring

.

w

arnin

G

High

Voltage:

Disconnect

all

power

bef

or

e

ser

vicing

or

installing

this

unit.

Multiple

power

sour

ces

ma

y

be

pr

esent.

F

ailur

e

to

do

so

ma

y

cause

pr

operty

damage,

per

sonal

injur

y,

or

dea

th.

BK

OR

C

F

BL

NOTE 3

SEE

GR

W H

W1

RD

R

BL

C

Y1

YL

Y2

G

TO THERMOSTAT

YL/PK

BL/PK

W H

LPS

HPS

RD

BR

RD

FC

RD

OR

VM

BK

IGN

FS

NOTE 3

SEE

PU

GR

GV

GAS VALVE

(ALT.) HONEYW ELL

BL

BL

GV

GAS VALVE

W. R.

PU

PU

MV

MV

YL

BL

L2

BL

BL

UN

US

ED

COOL

HE

AT

GR

BL

575

575/3/60

460/3/60

SEE NOTE 4

POWER SUPPLY

GR

S2

S1

BL

OR

BK

OR

L3

L2

L1

OR

RD

BK

BC

C

T3

T1

T2

PK

TB1

SMOKE/FIRE
DETECTOR
REPLACES JUMPER
W IRE

BR

OR

BK

460/575

TR

240

C

460

BL

BL

TR

24V

BL

VMR

3

1

2

WH

RD

EM

OR

BK

RD

OR

ALS

RS

YL

3

6

PLF

NOTE 2

2

1

4

5

PS

PU

YL

PU

YL

GR

BL

YL

YL

RD

DI

RD

YL

FS

BR

L1

WH

4
5
6

2

3

1

RD

RD

RD

PU

BL

ECON

11

8

12

9

7

10

GR

W H

LS

RD

RD

BK

BR

CM

COMP

PU

T1

T2

T3

BK

BK

OR

RD

BL

BL

L2

L1

C

RD

BK

YL

PU

BK

T2

T1

IIC

YL

GR

BK

YL

L3

OR

RD

T3

GND

460-575/3/60

0140L00871 REV B

SEE UNIT RATING PLATE FOR TYPE AND

SIZE OF OVER CURRENT PROTECTION.

SUPPLY VOLTAGE

460-575/3/60

YL

YELLOW

OR

ORANGE

BR

BROWN

RD

RED

BK

BLACK

WH

WHITE

PK

PINK

PU

PURPLE

BL

BLUE

WIRE CODE

GR

GREEN

YL/PK

YELLOW WITH PINK STRIP

BL/PK

BLUE WITH PINK STRIP

STAT

STAT

STAT

Y1

C

R

G

Y2

W

C

G

R

W

Y

TB1

TB1

C

Y

W

R

G

TB1

2 STAGE COOLING

C

BL

THERMOSTAT
FIELD WIRING

GR

C

WITH ECONOMIZER OPTION

WH

G

Y1

GR

YL

R

C

GR

WH

RD

R

W

WH

PK

Y1

Y/Y2

RD

YL

G

NO ECONOMIZER

W

R

G

BL

Y/Y2

W

YL

Y/Y2

Y1

RD

BL

RD

BK

OR

BC

BC

HIGH PRESSURE SWITCH

HPS

LOW PRESSURE SWITCH

LPS

HPS

LPS

460-575/3/60 0140L00871 REV B

4

1

TR

7

G

TO THERMOSTAT

R

IIC

9

Y1

W

Y

Y2

11

12

8

6

3

ECON

10

PS

ALS

NOTE 3

L1

4

5

F

FS

D1

C

H

LS

VM

EM

1

NOTE 2

C

5

2

PLF

6

3

GV

RS

C

L2

NOTE 3

IGN

FS

VMR

IIC

BC

VMR

3

1

3

L1

C

L1

COMP

T1

T1

T2

T3

T2

FC

C

T3

CM

L3

L2

C

L3

L2

BC

BLOWER CONTACTOR

BC

INDOOR BLOWER RELAY

IBR

AUXILLARY LIMIT SWITCH

FEMALE PLUG/CONNECTOR

INTEGRATED IGNITION CONTROL

CM

CONDENSER MOTOR

LS

LIMIT SWITCH

VENT MOTOR RELAY

VENT MOTOR

PRESSURE SWITCH

TERMINAL BLOCK (24V SIGNAL)

ROLLOUT SWITCH

VMR

VM

PS

PLF

TB1

RS

FAN CAPACITOR

CONTACTOR

GAS VALVE

IGNITOR

EQUIPMENT GROUND

FLAME SENSOR

EVAPORATOR MOTOR

FC

FUSE

F

C

GV

FS
GND

IGN

IIC

EM

COMPRESSOR

COMPONENT LEGEND

COMP

ALS

OPTIONAL HIGH
VOLTAGE

HIGH VOLTAGE

FIELD WIRING

LOW VOLTAGE

LINE VOLTAGE

FACTORY WIRING

LOW VOLTAGE

TR

TRANSFORMER

NOTES

CHECK

-

CHECK INPUT POWER
CHECK FUSE ON CONTROL

CHECK

PRESSURE SWITCH

GAS FLOW

REPLACE CONTROL

GAS VALVE

BAD SW ITCH

FLAME SENSOR

AUX. LIMIT OPEN

FLAME ROLLOUT

GAS PRESSURE

PRESSURE SWITCH

3 MIN. COMP.

BAD SW ITCH

STICKING GAS VALVE

MAIN LIMIT OPEN

ANTI-CYCLE TIMER

CHECK

EQUIP. STATUS

NO POWER OR

SWITCH

OPEN

SWITCH

OPEN ROLLOUT

IGNITION FAILURE

OPEN AUX. LIMIT

STATUS LIGHT

2 BLINKS

1 BLINK

ON

OFF

COMPRESSOR

OUTPUT DELAY

5 BLINKS

4 BLINKS

6 BLINKS

3 BLINKS

INTERNAL CONTROL

NORMAL OPERATION

PRESSURE SWITCH

PRESSURE SWITCH CLOSED

WITHOUT INDUCER ON

OPEN LIMIT SWITCH

FALSE FLAME SENSED

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

INSTALLER/SERVICEMAN

1. REPLACEMENT WIRE MUST BE THE SAME

SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).

2. ACCESSORY ECONOMIZER PLUG ADJACENT

TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO THE ECONOMIZER
ACCESSORY.

4. USE COPPER CONDUCTORS ONLY.

USE NEC CLASS 2 WIRE.

3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.