1407B***C*

Cooling Capacity
Total BTU/h

59,500

58,000

59,500

58,000

58,500

58,000

Sensible BTU/h

43,200

43,200

43,200

43,200

42,500

42,500

SEER / EER

13 / 11.0

13 / 11.1

13 / 11.0

13 / 11.1

13 / 11.0

13 / 11.1

Decibels

78

78

78

78

78

78

AHRI Reference #s

4385066

5368226

4385067

5368227

4397609

5368228

Gas Heating Capacity
High Input /Output kBTU/h

138 / 110.4

138 / 110.4

138 / 110.4

138 / 110.4

138 / 110.4

138 / 110.4

Low Input /Output kBTU/h

103 / 83

103 / 83

103 / 83

103 / 83

103 / 83

103 / 83

Steady State Efficiency (AFUE)

80

80

80

80

80

80

Temperature Rise Range (°F)

35-65 / 25-55

35-65 / 25-55

35-65 / 25-55

35-65 / 25-55

35-65 / 25-55

35-65 / 25-55

No. of Burners

6

6

6

6

6

6

Evaporator Motor / Coil
Motor Type

Belt

Belt

Belt

Belt

Belt

Belt

Indoor Nominal CFM

1,900

1,900

1,900

1,900

1,900

1,900

Piston Size (Cooling)

0.086

0.086

0.086

0.086

0.086

0.086

Filter Size (#)

14 x 20 x 2 (4)

14 x 20 x 2 (4)

14 x 20 x 2 (4)

14 x 20 x 2 (4)

14 x 20 x 2 (4)

14 x 20 x 2 (4)

Drain Size (NPT)

¾"

¾"

¾"

¾"

¾"

¾"

R-410A Refrigerant Charge (oz.)

165

100.8

165

100.8

165

100.8

Face Area (ft²)

7.8

7.8

7.8

7.8

7.8

7.8

Rows Deep/ Fins per Inch

4 / 16

4 / 16

4 / 16

4 / 16

4 / 16

4 / 16

Tube Diameter - Material

5/16 - Copper

5/16 - Copper

5/16 - Copper

5/16 - Copper

5/16 - Copper

5/16 - Copper

Belt Drive Evap Fan Data
# of Wheels (D x W)

1 (11" x 10")

1 (11" x 10")

1 (11" x 10")

1 (11" x 10")

1 (11" x 10")

1 (11" x 10")

Motor Sheave / Blower Sheave

VL44 X ⅝ / AK61 X 1 VL44 X ⅝ / AK61 X 1 VL44 X ⅝ / AK61 X 1 VL44 X ⅝ / AK61 X 1 VL44 X ⅝ / AK61 X 1 VL44 X ⅝ / AK61 X 1

Belt

AX53

AX53

AX53

AX53

AX53

AX53

Condenser Fan / Coil
Horsepower / RPM

¼ / 1,090

¼ / 1,090

¼ / 1,090

¼ / 1,090

¼ / 1,075

¼ / 1,075

Fan Diameter/ # Fan Blades

22 / 4

22 / 4

22 / 4

22 / 4

22 / 1

22 / 1

Outdoor Nominal CFM

3,800

3,800

3,800

3,800

3,800

3,800

Face Area (ft²)

17.0

13.0

17.0

13.0

17.0

13.0

Rows Deep/ Fins per Inch

2 / 18

2 / 27

2 / 18

2 / 27

2 / 18

2 / 27

Tube Diameter - Material

5/16 - Copper

5MM - Copper

5/16 - Copper

5MM - Copper

5/16 - Copper

5MM - Copper

Compressor
Quantity / Stage / Type

1 / Single / Scroll 1 / Single / Scroll 1 / Single / Scroll 1 / Single / Scroll 1 / Single / Scroll 1 / Single / Scroll

Compressor RLA / LRA

16 / 110

16 / 110

7.8 / 52

7.8 / 52

5.7 / 38.9

5.7 / 38.9

Electrical Data
Voltage-Phase-Frequency

208/230-3-60

208/230-3-60

460-3-60

460-3-60

575-3-60

575-3-60

Indoor Blower HP / FLA (STD Static)

1.0 / 3.8

1.0 / 3.8

1.0 / 1.9

1.0 / 1.9

1.5 / 2.3

1.5 / 2.3

Belt-Drive High Static FLA

1.5 / 5.0

1.5 / 5.0

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

1.5 / 2.5

Indoor Blower LRA

24

24

13

13

12

12

Max External Static

1.0

1.0

1.0

1.0

1.0

1.0

Outdoor Fan HP / FLA

¼ / 1.40

¼ / 1.40

¼ / 0.8

¼ / 0.8

¼ / 0.6

¼ / 0.6

Min. Circuit Ampacity¹

25

25

12

12

10

10

Max. Overcurrent Protection ²

40 amps

40 amps

20 amps

20 amps

15 amps

15 amps

Power Supply Conduit Hole

1.125

1.125

1.125

1.125

1.125

1.125

Low-Voltage Conduit Hole

½"

½"

½"

½"

½"

½"

Operating/Shipping Weight (lbs)

630/ 655

620/ 645

630/ 655

620/ 645

630/ 655

620/ 645

¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

² May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

• Always check the S&R plate for electrical data on the unit being installed.

• When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for

208/230V units, increase by 3.75A for 460V units, and by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.

Advertising