Description of status cause of status indication, Diagnostic status codes, Traction status code – GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 39: Sx transistor control page 39

Advertising
background image

DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 39

January 2000

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-69

The power steering coil current is too
high during the run mode.

This status code will be displayed when the current in the
power steering driver circuit exceeds current limit during the
run mode. The control is reset by recycling the key switch.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Controller

SYMPTOM
Control will not operate.

POSSIBLE CAUSE

=

Shorted power steering control coil

=

Short between wires connecting to the
power steering coil (wire # 10 and 60)


If the power steering coil resistance is correct
then:

=

Defective control. Replace control unit

KEY SWITCH

L

P7

P1

P17

P2 P6

P9

P3

P12 P8

P4

P5

SEAT

SW.

ST

AR

T

SW.

FOR

. S

W

.

R

EV.

SW.

P10

P18

PY7
PY12
PY10
PY11

SP

P1

P5

P4

P2

FU7

TO

ACCESSORIES

FU6

P3

OSCILLATOR CARD

LEFT CONTROL

FU1

STEER
ANGLE

POT

LINE

POWER

CONNECTIONS

LEFT CONTROL

POS

A1

F1

NEG

A2

F2

FIE

L

D

A

RM

A

T

URE

ACC POT

BDI INTERRUPT

+

-

SP

SP

FU4

A1

FU2

P

P

POWER

CONNECTIONS

RIGHT CONTROL

POS

A1

F1

NEG

F2

FIE

L

D

A

RM

A

T

URE

FU5

BRAKE SW.

A2

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-76

Capacitor (1C) voltage too high.

This status code will be displayed when the voltage on the
capacitor goes above limit voltage* during the regenerative
braking cycle.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Controller







SYMPTOM
Line contactor opens and closes, then
opens and can only close by opening
and closing the key switch.

POSSIBLE CAUSE

=Unplugging the battery connector

during regenerative braking.

=Line contactor bouncing open during

regen.

=Main power fuse opening during

regen.

=Intermittent battery plug connection.


* Limit Voltage:
Limit Batt.
50V 36V
70V 48V
96V 72/80V

KEY SWITCH

L

P7

P1

P17

P2 P6

P9

P3

P12 P8

P4

P5

SEAT

SW.

ST

AR

T

SW.

FOR

. S

W

.

R

EV.

SW.

P10

P18

PY7
PY12
PY10
PY11

SP

P1

P5

P4

P2

FU7

TO

ACCESSORIES

FU6

P3

OSCILLATOR CARD

LEFT CONTROL

FU1

STEER
ANGLE

POT

LINE

POWER

CONNECTIONS

LEFT CONTROL

POS

A1

F1

NEG

A2

F2

FIE

L

D

A

RM

A

T

URE

ACC POT

BDI INTERRUPT

+

-

SP

SP

FU4

A1

FU2

P

P

POWER

CONNECTIONS

RIGHT CONTROL

POS

A1

F1

NEG

F2

FIE

L

D

A

RM

A

T

URE

FU5

BRAKE SW.

A2

Advertising
This manual is related to the following products: