DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 42

January 2000

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-93

Steering pump motor brush wear
indicator has detected worn brush.

This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at battery volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Steer

Pump

Motor

Brush Wear

Indicator



SYMPTOM
Status code flashes “on and off”.

POSSIBLE CAUSE
User defined status code is displayed by motor
brush sensor closure to battery positive.

Plug P3 (pump) is shorted to positive.

Defective input switch (shorted).

Defective TMM card.

Defective pump card.

SC93

POS

P3

USER SW

WHEN SR Series PUMP

CONTROL IS USED

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-93

Steering pump motor brush wear
indicator has detected worn brush.

This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at battery volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Steering

Pump

Motor

Brush Wear

Indicator





SYMPTOM
Status code flashes “on and off”.

POSSIBLE CAUSE
User defined status code is displayed by motor
brush sensor closure to battery positive.

Plug P4 (pump) is shorted to positive.

Defective input switch (shorted).

Defective TMM card.

Defective pump card.

SC93A

POS