Set-up mode – GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 56

Advertising
background image

ADJUSTABLE FEATURES

SX TRANSISTOR CONTROLS

Page

56

January 2000

Section 6.3 Set-up Function Procedures


With the Handset connected, hold down the CONT key and

turn on the key switch. This will place you in the set-up

mode, ready to monitor or adjust control function settings.


NOTE: The term “Push” means to depress key for
approximately one second.

Section 6.3.1 Setup Mode

SET-UP MODE

Hold Down CONT

And Turn On Key

8 8 8 8

Segment Check

Displayed

ACTION

DISPLAY

SHOWS

REMARKS

Push Function Number

U 0 0 5

Selected Function No.

Is Displayed

After One Second

Time Delay

0 8 5

Stored Value For The
Function Is Displayed

Push CONT

0 8 5

Display Value

Will Blink

Change Value With

Adjustment Knob

Value Changes

While Blinking

Push STORE

125

New Value Stored And

Blinking Stops

Push ESC

8 8 8 8

Segment Check

Displayed

125

At this point, another function can be monitored/changed

by pushing another function number, or the vehicle can be
placed in the run mode by holding the ESC key down for

one second or longer. The display will return to either the

diagnostics mode, the BDI display, or a blank display (if

BDI is not used and there are no fault codes). The vehicle

can now be operated with the Handset connected, or the

Handset can be disconnected before operation.


NOTE: You can return to the segment check mode at any
time, by holding down the ESC key until 8888 appears in
the display.


Section 6.3.2 Status Code Scrolling

The SX family of controllers furnishes a function register

that contains the last 16 “stored status codes” that shut

down vehicle operation (a PMT type fault that is reset by

cycling the key switch) and the battery state of charge

reading at the time the fault occurred. The first of the 16

status codes will be overwritten each time a new status

code occurs. This stored status code register can be

cleared from memory by using the Handset.

Key Switch Off

Push ESC and CONT

At The Same Time

Release ESC and CONT

Key

Status Code Displayed

Push CONT Key

Displays Battery

State-Of-Charge When

Fault Occurred

Push CONT Key

Display Hourmeter Reading

When Fault Occurred

Push CONT Key

Push CONT Key

ACCESSING STORED STATUS CODES

WITH GE HANDSET

Section 6.3.3 SX Family Handset, Plug
Connections and Outline Drawing

“Y” Plug

Handset Cable Part Number - 325B1002G1