DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 41

January 2000

Section 4.6 TMM Status Codes

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-90

Traction motor temperature has
exceeded maximum temperature limit.

This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at zero volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Motor

Temperature



SYMPTOM
Status code flashes “on and off”.

POSSIBLE CAUSE
User defined status code is displayed by switch
closure to battery negative.

Plug P16 (pump) is shorted to battery negative.

Defective input switch (shorted).

Defective TMM card.

Defective pump card.

P16

SC90

NEG

USER SW

WHEN SR Series PUMP

CONTROL IS USED

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-91

Pump motor temperature has
exceeded maximum temperature limit.

This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at zero volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Motor

Temperature





SYMPTOM
Status code flashes “on and off”.

POSSIBLE CAUSE
User defined status code is displayed by switch
closure to battery negative.

Plug P11 (pump) is shorted to battery negative.

Defective input switch (shorted).

Defective TMM card.

Defective pump card.

P11

SC91

NEG

USER SW

WHEN SR Series PUMP

CONTROL IS USED


Advertising