No graphic for this status code – GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 46

Advertising
background image

DIAGNOSTIC STATUS CODES

TRANSISTOR PUMP CONTROL

Page 46

January 2000

Section 4.7 Pump Control Codes

PUMP

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-117

“Card Type” selection is invalid.

This status code will be displayed when the card type
selection value is set to an invalid number.

MEMORY RECALL

NO

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Pump

Controller

SYMPTOM
Control will not operate.

POSSIBLE CAUSE
Invalid card type selection.

=Review function 17 in the Handset

Instruction sheets. Adjust and set
card type value as instructed by OEM
service manual.


Verify that the correct logic card
catalog number is installed in the
controller.

NO

GRAPHIC

FOR THIS

STATUS CODE

PUMP

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-127

Control logic card power supply is less
than 10 VDC.

This status code is displayed when the logic card
power supply is less than 10 volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Pump

Controller


SYMPTOM
Control will not operate.

POSSIBLE CAUSE

Discharged Battery

=Check battery to insure proper state of

charge.


Loose connection at P1.

=Insure that the wire connection at P1 is

tight.


Defective logic card

=Replace control.

FU3

KEY SWITCH

P1 P2

FU2

POWER CONNECTIONS

POS

A1

NEG

A2

FI

E

L

D

A

R

MA

TURE

+

-

FU1

LINE

Advertising