GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 43

Advertising
background image

DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 43

January 2000

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-94

Traction motor brush wear indicator
has detected worn brush.

This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at battery volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Motor

Brush Wear

Indicator




SYMPTOM
Status code flashes “on and off”.

POSSIBLE CAUSE
User defined status code is displayed by motor
brush sensor closure to battery positive.

Plug P5 (pump) is shorted to positive.

Defective input switch (shorted).

Defective TMM card.

Defective pump card.

SC94

POS

P5

USER SW

WHEN SR Series PUMP

CONTROL IS USED

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-94

Traction motor brush wear indicator
had detected worn brush.

This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at zero volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Motor

Brush Wear




SYMPTOM
Status code flashes “on and off”.

POSSIBLE CAUSE
User defined status code is displayed by motor
brush sensor closure to battery positive.
.
Plug P6 (pump) is shorted to positive.

Defective input switch (shorted).

Defective TMM card.

Defective pump card.

SC94A

POS

P6

USER SW

WHEN SR Series PUMP

CONTROL IS USED

Advertising
This manual is related to the following products: