Installation continued – Garland RADIANT CHAR-BROILER 4522970 REV 1 User Manual

Page 7

Advertising
background image

Part # 4522970 Rev 1 (10/28/09)

Page 7

Rigid Connections

Double-check any installer-supplied intake pipes visually

and clear any dirt particles, threading chips, or other foreign

matter before installing in a service line . Those particles will

clog orifices when gas pressure is applied .

Flexible Couplings & Connectors

If the unit is to be installed with flexible couplings and/or

quick-disconnect fittings, for an appliance equipped with

casters, the installation shall be made with a heavy duty, AGA

design-certified commercial flexible connector or at least

3/4” NPT (with suitable strain relief) in compliance with the

Standard for Connectors for Moveable Gas Appliances, ANSI

Z21 .69/CSA 6 .16, Addenda Z21 .69B-2006/CSA 6 .16B-2006 (or

latest edition), and a quick-disconnect device that complies

with the Standard for Quick Disconnects for Use with Gas

Fuel, ANSI Z21 .41/CSA 6 .9, Addenda Z21 .41A-2005/CSA

6 .16A-2005 (or latest edition), and adequate means must be

provided to limit the movement of the appliance without

depending on the connector and the quick-disconnect

device or its associated piping to limit the appliance

movement and the location(s) where the restraining means

may be attached to the appliance shall be specified .

Further, if the unit is to be installed on a non-combustible

surface that is equipped with casters, means must be

provided to limit the movement of the unit with casters .

Manual Pilot Valve

Check all gas connections for leaks using a soapy solution

before lighting any pilots! DO NOT USE AN OPEN FLAME

TO CHECK FOR LEAKS! Putting an open flame beside a new

connection is not only dangerous, but will often miss small

leaks that a soapy solution would find .

All Garland appliances are adjusted and tested before

leaving the factory, effectively matching them to sea

level conditions . Adjustments and calibrations to assure

proper operation may be necessary on installation to meet

local conditions, low gas pressure, differences in altitude,

variations in gas characteristics, to correct possible problems

caused by rough handling or vibration during shipment, and

are to be performed only by qualified service personnel .

These adjustments are the responsibility of the customer,

installer and/or dealer and are not covered by the Garland

warranty .

All burners are equipped with continuous electronic spark

electrodes to insure flame is on at all times during operation .

Continuous sparking is intended to remain energized until

power is manually switched off .

WARNING: All connections must be sealed with a joint

compound suitable for LP gas, and all connections must be

tested with a soapy solution before lighting any pilots!

Start Up

Before initial lighting or if unit does not operate at all check

to see if:

1 . Main gas supply shut off to appliance is open .

2 . Electric power supply power and cord Nema 5-15P has

been plug into an appropriate 120V 15Amp 60Hz outlet .

For daily start up:

1 . Models HEEE-24CL and HEEE-36CL have one power

switch . Once pushed to the “ON” position an igniter

supplies a continuous spark to the burners igniting the

gas to all burners simultaneously . At the same time the

power switch opens up the gas flow to burners .

2 . Models HEEE-48CL and HEEE-60CL have two power

switches which operate in the same manner as the

single switch above . Each switch operates separately

allowing the operator to run two sections of the broiler

independently . On the HEEE-48CL the switch on the far

left operates burners 1 to 5 . The power switch on the

right will operate burners 6 to 9 . On the HEEE-60CL the

left switch controls burners 1 to 6 and the right switch

controls burners 7 to 11 .

3 . If burners do not ignite, shutdown power to the unit,

and wait 5 minutes before repeating ignition . If repeated

ignition fails, shutdown power to the unit and contact a

service person .

4 . Your broiler is an energy saving unit, all burners are pre-

set at the factory to run at a consistent steady flame . No

adjustment should be attempted by the operator .

Shut Down

1 . For shutting down overnight, on all models turn the

power switch(es) to the “OFF” position .

INSTALLATION Continued

Advertising