Manitowoc Ice Q User Manual

Page 20

Advertising
background image

Installation Instructions

Section 2

2-10

Part Number 000001530

Ice Machine Head Section Water Supply and Drains

POTABLE WATER SUPPLY

Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.

POTABLE WATER INLET LINES

Follow these guidelines to install water inlet lines:

Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)

If water pressure exceeds the maximum
recommended pressure 80 psig (551.5 kPA), obtain
a water pressure regulator from your Manitowoc
distributor.

Install a water shut-off valve for ice making potable
water.

Insulate water inlet lines to prevent condensation.

DRAIN CONNECTIONS

Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:

Drain lines must have a 1.5 inch drop per 5 feet of
run (2.5 cm per meter), and must not create traps.

The floor drain must be large enough to
accommodate drainage from all drains.

Run separate bin and ice machine drain lines.
Insulate them to prevent condensation.

Vent the bin and ice machine drain to the
atmosphere. The ice machine drain requires an 18”
vent.

Important

If you are installing a Manitowoc water filter system,
refer to the Installation Instructions supplied with the
filter system for ice making water inlet connections.

Advertising