Operational Checks

GENERAL

Manitowoc ice machines are factory-operated and
adjusted before shipment. Normally, a newly installed ice
machine does not require any adjustment.

To ensure proper operation, always follow the
Operational Checks:

when starting the ice machine for the first time

after a prolonged out of service period

after cleaning and sanitizing

NOTE: Routine adjustments and maintenance
procedures outlined in this manual are not covered by
the warranty.

WATER LEVEL

The water level sensor is set to maintain the proper
water level above the water pump housing. The water
level is not adjustable.

If the water level is incorrect, check the water level probe
for damage (probe bent, etc.). Repair or replace the
probe as necessary.

Water Level Probe

ICE THICKNESS CHECK

After a harvest cycle, inspect the ice cubes in the ice
storage bin. The ice thickness probe is factory-set to
maintain the ice bridge thickness at 1/8" (3.2 mm).

NOTE: Make sure the water curtain is in place when
performing this check. It prevents water from splashing
out of the water trough.

1. Inspect the bridge connecting the cubes. It should

be about 1/8" (3.2 mm) thick.

2. If adjustment is necessary, turn the ice thickness

probe adjustment screw clockwise to increase
bridge thickness, counterclockwise to decrease
bridge thickness.

NOTE: Turning the adjustment 1/3 of a turn will change
the ice thickness about 1/16" (1.5 mm).

Ice Thickness Check

3. Make sure the ice thickness probe wire and the

bracket do not restrict movement of the probe.

Important

CVD2075 Condensing Units

A scroll compressor must be operated for a
minimum break in period of 72 hours before full ice
production capacity will be reached.

SV1616A

ADJUSTING SCREW

SV1208

1/8” ICE BRIDGE THICKNESS