Manitowoc Ice Q User Manual

Page 30

Advertising
background image

Installation Instructions

Section 2

2-20

Part Number 000001530

Installation Checklist

Is the Ice Machine level?

Has all of the internal packing been removed?

Have all of the electrical and water connections

been made?

Has the supply voltage been tested and checked

against the rating on the nameplate?

Is there proper clearance around the ice machine

for air circulation?

Has the ice machine been installed where

ambient temperatures will remain in the range of
35° - 110°F (1.7° - 43.3°C)?

Has the ice machine been installed where the

incoming water temperature will remain in the
range of 33° - 90°F (0.6° - 32.2°C)?

Are the ice machine and bin drains separately

vented?

Are all electrical leads free from contact with

refrigeration lines and moving equipment?

Has the owner/operator been instructed regarding

maintenance and the use of Manitowoc Cleaner
and Sanitizer?

Has the warranty registration card been sent to

the factory?

Has the ice machine and bin been sanitized?

Has the ice machine receiver service valve been

opened 100%?

Are the ice machine line set shut-off valves open

100%?

Does the condenser fan motor(s) operate

properly after start-up?

Have all the refrigeration fittings and joints been

leak checked?

Is the line set routed properly?

Is a refrigeration oil trap (S-trap) installed if the

condenser is installed 21 to 35 feet (6.1 to 10.7m)
above the ice machine head?

Has the CVD® condensing unit been installed to

prevent any roofing damage?

Have the refrigeration lines been insulated and

secured properly to prevent vibration?

Has the remote condensing unit been located

where ambient temperatures will remain in the
range of -20° to 120°F (-28.9° to 49°C)?

Is the toggle switch set to ice?

Is the ice thickness control set correctly?

Is the water trough drain plug installed? (The

drain plug is taped to the top of the water pump)

Does the condenser fan motor(s) operate

properly after start-up?

Is the direction of rotation correct on a CVD2075

3ph scroll compressor?

Advertising