F. Remove the water pump.

Disconnect the water pump power cord.

Disconnect the hose from the pump outlet.

Loosen the screws securing the pump mounting
bracket to the bulkhead.

Lift the pump and bracket assembly off the screws.

Remove water pump assembly from ice machine.Do
not soak the water pump motor in cleaner or sanitizer
solution

G. Remove the water trough

Remove the quarter turn fasteners (turn
counterclockwise) securing the trough in place.

Lift up and forward on the front of the water trough
while allowing the rear of the water trough to drop.

Remove the water trough from the ice machine.