Drain connections, Ventilation connections – Moyer Diebel MD-66 User Manual

Page 11

Advertising
background image

3

Installation

Drain Connections

1. The 1-1/2" drain line was removed and packed inside the dishwasher prior to shipping.

Install the drain line once the dishwasher has been placed in its final location.

2. Connect the 1-1/2" NPT drain line to above a drain sink or to a 1-1/2" or larger drain line

connection.

3. Observe all local plumbing and sanitary codes when installing.

1.

DO NOT VENT THE DISHWASHER INTO WALLS,
CEILINGS OR ENCLOSED PLACES.

2.

Vent stacks with adjustable dampers are supplied with the dishwasher to connect house
vent.

3.

Connect stainless steel water-tight duct inside the 4" x 16"/ 106mm x 407mm vent
stacks supplied with the dishwasher.

4.

A minimum of 6 air changes per hour of kitchen is recommended

Ventilation Guidelines:

Dishwasher without a prewash tank option:
Load end- 200 CFM @ 1/4" SP/ 95 Liters/second

Unload end- 400 CFM @ 1/4" SP/ 189 Liters/second

Dishwasher with a Prewash tank option:
Load end- 150 CFM @ 1/4" SP/ 95 Liters/second
Unload end- 400 CFM @ 1/4" SP/ 189 Liters/second

Ventilation Connections

Advertising