83 plate 3, Plate 4, Normal operation sequence – Moyer Diebel MD-66 User Manual

Page 91: Rcm status/jumpers

Advertising
background image

83

Plate 3:

1. Doors closed.

2. POWER light ON.

3. Floats up.

4. Tanks full.

5. Tank heat enabled.

6. Booster heat enabled.

7. Initial fill complete.

8. Start push button

pressed and released.

9. RUN LIGHT ON and

Green light on front
panel ON.

Plate 4:

1. Doors closed.

2. POWER light ON.

3. Floats up.

4. Tanks full.

5. Tank heat enabled.

6. Booster heat enabled.

7. Rack inserted into

machine/rack switch
activated.

8. RCM timer active.

Timer will begin count-
ing down the 90 sec.
interval when the rack
switch is de-activated

9. Pumps and drive motor

running.

Rack Control Module Operation

Rinse Flt L

Wa

sh Flt L

Wa

sh Flt U

Final Rinse

Rack Switch

Jam Switch

Table Limi

t

Stop

Start

Pause Power

DR Level Rinse Flt U

Prewash Flt L

Prewash Flt U

Run

H7

H5

H3

H1

H2

H4

H6

AA

Prewash

DR

Ta

nk

Rinse

Tank

Digital Display

Rinse

Reset

DR Pump

Pumps

Rinse Aid

Prewash Fill

Wash Fill

Final Rinse

Run Light

DR/Rinse Heat

Wash Heat

Booster Heat

RCM Status/Jumpers

= Indicator ON

= Indicator OFF

NOT USED

NOT USED

NOT USED

NOT USED

START light comes

on when pressed

and goes out when

it is released.

Rinse Flt L

Wa

sh Flt L

Wa

sh Flt U

Final Rinse

Rack Switch

Jam Switch

Table Limi

t

Stop

Start

Pause Power

DR Level Rinse Flt U

Prewash Flt L

Prewash Flt U

Run

H7

H5

H3

H1

H2

H4

H6

AA

Prewash

DR

Ta

nk

Rinse

Tank

Digital Display

Rinse

Reset

DR Pump

Pumps

Rinse Aid

Prewash Fill

Wash Fill

Final Rinse

Run Light

DR/Rinse Heat

Wash Heat

Booster Heat

RCM Status/Jumpers

= Indicator ON

= Indicator OFF

NOT USED

NOT USED

NOT USED

NOT USED

PUMPS light ON shows

the pumps are enabled and

the RCM Timer is active.

Normal Operation Sequence