Rack control module (rcm) operation, Rcm status/jumpers – Moyer Diebel MD-66 User Manual

Page 89

Advertising
background image

81

Rack Control Module Operation

The timer controls the drive motor, wash pump and the MD-66 prewash pump.

The timer is internal to the RCM. The PUMPS output indicator light shows the RCM Timer is
active.

The timer output comes on when the rack switch opens, this turns on the PUMPS output.
When the rack switch closes the timer counts for 90-seconds.
After 90-seconds, the PUMPS output is turned off.
Inserting another rack during the timing resets the timer to 90-seconds.

The red input lights below show how the RCM inputs affect the timer’s operation,

START light ON - Enables automatic operation

STOP light ON - Disables automatic operation

RACK SWITCH light OFF - Starts the timer

TABLE LIMIT light OFF - Pauses the timer. Timing resumes when the light comes back on.

PAUSE light OFF - Pauses the timer. Timing resumes when the light comes back on.

JAM light OFF - Stops the machine and disables automatic operation. The front panel Start
push button must be pressed to resume automatic operation and a dish rack
must be inserted to start the timer.

Rack Control Module (RCM) Operation

RCM Timer Operation

Run

AA

Prewash

DR

Ta

nk

Rinse

Tank

Reset

RCM Status/Jumpers

NOT USED

NOT USED

RUN -

ON when power is turned on to the RCM.

THIS RUN LIGHT DOES NOT MEAN THAT
THE DISHWASHER IS READY TO OPERATE.

JUMPERS:

Prewash -

Enables the prewash input and output

functions.

AA, DR Tank, Rinse Tank - NOT USED

Reset Button - NOT USED

The RCM Status/Jumper Section contains one red indicator light

and four jumpers that are associated with the set-up of the RCM.

RCM Status and Jumper Section

Advertising