Moxa Technologies CP-104UL User Manual

Page 39

Advertising
background image

Software Installation

Smartio CP-104UL User’s Manual 3-25

2. Click on the desired CP-168U board, and then click on [Properties].

3. Select the [Ports Configuration] tab, click on the specific port, and then click on the [Port

Setting] button.

4. Check the Auto Enumerating COM Name check-box to assign continuous COM numbers for

subsequent ports. For example, if COM3 is assigned to Port 1, then COM4 will be
automatically assigned to Port 2.

5. Select an Rx FIFO Trigger from the Rx FIFO Level pull-down list. Rx FIFO trigger levels

from High to Low are available, with a default value is High Level (120 bytes). Check Set the
change to all ports check-box to apply the just defined Rx FIFO Trigger to all ports.

6. Select a Tx FIFO Size from the Tx FIFO Level pull-down list. Tx FIFO Level from High to

Low are available, with a default value is High Level (128 bytes). Check Set the change to all
ports check-box to apply the just defined Tx FIFO Size to all ports.

CP-104UL v2

CP-104UL v1

Tx FIFO

Rx FIFO

Tx FIFO

Rx FIFO

High 128 120 64 56
Middle 64 60 32

28

Low 1 1 1 1

Unit: Bytes