Connection cables and cable wiring, Rs-232 cable wiring, 5 connection cables and cable wiring -1 – Moxa Technologies CP-104UL User Manual

Page 63: Rs-232 cable wiring -1, 5connection cables and cable wiring

Advertising
background image

5

5

Connection Cables and Cable Wiring

In this chapter, we illustrate the possible connections and cable wiring for the CP-104UL boards.

In serial data communications, DTE stands for Data Terminal Equipment, such as a PC’s COM1/2,
serial printers, and terminals, and DCE stands for Data Communication Equipment, such as
modems.

RS-232 Cable Wiring

Board Pinouts—DB44 Female

RS-232

Port 1

Port 2

Port 3

Port 4

13

TxD 9

TxD 5

TxD 1 TxD

14 RxD

10 RxD

6 RxD

2 RxD

15 RTS

11 RTS

7 RTS

3 RTS

28 CTS

24 CTS

20 CTS

16 CTS

29 DTR

25 DTR

21 DTR

17 DTR

30 DSR

26 DSR

22 DSR

18 DSR

42 DCD

39 DCD

35 DCD

31 DCD

44 GND

41 GND

37 GND

33 GND

Advertising