background image

Connection Option (Opt8x) and Cable Wiring

Smartio C168H/PCI User’s Manual

5-3

Type 1: To connect S

Sm

maarrttiioo C168H/PCI to a DTE device.

PC COM2 port, Serial Printer,
Terminal, or any DTE Device

Opt8A/S

Straight-through Cable

Opt8A/S

DTE Device

DB25 Female

DB25 Male

RxD

2

2

TxD

TxD

3

3

RxD

CTS

4

4

RTS

RTS

5

5

CTS

DTR

6

6

DSR

DSR

20

20

DTR

GND

7

7

GND

DCD

8

8

DCD

PC COM2 port, Serial Printer,
Terminal, or any DTE Device

Opt8B/C

Null Modem Cable

Opt8B/C

DTE Device

DB25 Male

DB25 Male

TxD

2

2

TxD

RxD

3

3

RxD

RTS

4

4

RTS

CTS

5

5

CTS

DSR

6

6

DSR

DTR

20

20

DTR

GND

7

7

GND

DCD

8

8

DCD