Plasma cutting system practices, 4. plasma cutting system practices – Miller Electric ICE-100T User Manual

Page 24

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-201 872 Page 20

Ref. 803 640-A / 801 400-B / Ref. 802 878

5-4. Plasma Cutting System Practices

Pulling rather than pushing the torch

makes cutting easier. Use a proper guide

or template for accurate cutting operations.

The pilot arc starts immediately
when trigger is pressed.

Maintain approximately a 90

°

angle to the

workpiece surface for proper cutting results.

Always connect work clamp to a clean,

paint-free location on metal workpiece, as

close to cutting area as possible.

.

Set correct air pressure for process:
75 PSI (517 kPa) for cutting,
60 PSI (414 kPa) for gouging.

90

°

DO NOT start pilot arc without cutting or

gouging as this shortens the service life

of the nozzle and electrode.

Sparks should pass through the workpiece

and out the bottom when cutting.

If sparks flare back from surface, this

usually is an indication that either travel

speed is too fast, amperage is set too low,

or consumables are worn.

When doing non-shielded cutting, maintain

approximately 1/8 in standoff between

electrode and surface.

1/8 in

(3.2 mm)

DO NOT put pressure on shield when

drag cutting; instead, slide shield along

the surface for proper cutting results.

Wt

Advertising