Miller Electric ICE-100T User Manual

Page 30

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-201 872 Page 26

6-5.

+24 Volts DC Hot Contacts For Isolated Input Module Operation

804 041-A

Y

Turn off and disconnect
input power.

Control board PC1 can supply +24
volts dc from receptacle RMT2 to
operate a customer-supplied
isolated input module for the Okay
To Move signal.

1

Control Board PC1

2

Receptacle RMT1

3

Receptacle RMT2

4

Receptacle RC61

Move plug from RMT1 into
receptacle RMT2 on PC1. Be
sure remote control cable plug is
connected to RC61 on rear of
unit.

If voltage sensing is required, see
Section 6-8.

Install wrapper on unit.

Required Items:

Customer-supplied isolated input
module.

.

Plasma cutter is shipped from
the factory with plug connected
to receptacle RMT1 (dry
contacts).

1

Tools Needed:

5/16 in

Remote Control Cable

Remote

Start

White

Red

Black

Green

+24 VDC

3

4

Output

Okay To

Move

+

.

+24 volts dc will activate relay coil after unit is triggered and
the cutting arc is initiated.

2

Advertising
This manual is related to the following products: