Recommended operating conditions – Motorola TMS320C6711D User Manual

Page 62

Advertising
background image

TMS320C6711D

FLOATINGĆPOINT DIGITAL SIGNAL PROCESSOR

SPRS292A − OCTOBER 2005 − REVISED NOVEMBER 2005

62

POST OFFICE BOX 1443

HOUSTON, TEXAS 77251−1443

absolute maximum ratings over operating case temperature range (unless otherwise noted)

Supply voltage range, CV

DD

(see Note 2)

− 0.3 V to 1.8 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Supply voltage range, DV

DD

(see Note 2)

−0.3 V to 4 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Input voltage range

−0.3 V to DV

DD

+ 0.5 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Output voltage range

−0.3 V to DV

DD

+ 0.5 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operating case temperature ranges, T

C

(default)

0

_

C to 90

_

C

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

(A version) [

C6711DGDPA and C6711DZDPA

]

−40

_

C to105

_

C

. . .

Storage temperature range, T

stg

−65

_

C to 150

_

C

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and

functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

NOTE 2: All voltage values are with respect to VSS

.

recommended operating conditions

MIN

NOM

MAX

UNIT

CVDD

Supply voltage, Core

−250 only

1.33

1.4

1.47

V

CVDD

Supply voltage, Core

1.14§

1.20§

1.32

V

DVDD

Supply voltage, I/O

3.13

3.3

3.47

V

VSS

Supply ground

0

0

0

V

VIH

High-level input voltage

All signals except CLKS1, DR1, and RESET

2

V

VIH

High-level input voltage

CLKS1, DR1, and RESET

2

V

VIL

Low-level input voltage

All signals except CLKS1, DR1, and RESET

0.8

V

VIL

Low-level input voltage

CLKS1, DR1, and RESET

0.3*DVDD

V

IOH

High-level output current¶

All signals except ECLKOUT, CLKOUT2, CLKS1, and
DR1

–8

mA

IOH

High-level output current¶

ECLKOUT and CLKOUT2

–16

mA

IOL

Low-level output current¶

All signals except ECLKOUT, CLKOUT2, CLKS1, and
DR1

8

mA

IOL

Low-level output current¶

ECLKOUT and CLKOUT2

16

mA

CLKS1 and DR1

3

mA

TC

Operating case
temperature

Default

0

90

_

C

VOS

Maximum voltage during overshoot (See Figure 19)

4#

V

VUS

Maximum voltage during undershoot (See Figure 20)

−0.7#

V

TC

Operating case
temperature

A version (C6711DGDPA and C6711DZDPA)

–40

105

_

C

‡ The core supply should be powered up prior to (and powered down after), the I/O supply. Systems should be designed to ensure that neither

supply is powered up for an extended period of time if the other supply is below the proper operating voltage.

§ These values are compatible with existing 1.26−V designs.
¶ Refers to DC (or steady state) currents only, actual switching currents are higher. For more details, see the device-specific IBIS models.
# The absolute maximum ratings should not be exceeded for more than 30% of the cycle period.