Parameter measurement information, Signal transition levels – Motorola TMS320C6711D User Manual

Page 64

Advertising
background image

TMS320C6711D

FLOATINGĆPOINT DIGITAL SIGNAL PROCESSOR

SPRS292A − OCTOBER 2005 − REVISED NOVEMBER 2005

64

POST OFFICE BOX 1443

•

HOUSTON, TEXAS 77251−1443

PARAMETER MEASUREMENT INFORMATION

Transmission Line

4.0 pF

1.85 pF

Z0 = 50

Ω

(see note)

Tester Pin Electronics

Data Sheet Timing Reference Point

Output
Under
Test

NOTE: The data sheet provides timing at the device pin. For output timing analysis, the tester pin electronics and its transmission line effects

must be taken into account. A transmission line with a delay of 2 ns or longer can be used to produce the desired transmission line effect.
The transmission line is intended as a load only. It is not necessary to add or subtract the transmission line delay (2 ns or longer) from
the data sheet timings.

42

Ω

3.5 nH

Device Pin
(see note)

Input requirements in this data sheet are tested with an input slew rate of < 4 Volts per nanosecond (4 V/ns) at the device pin.

Figure 16. Test Load Circuit for AC Timing Measurements

signal transition levels

All input and output timing parameters are referenced to 1.5 V for both “0” and “1” logic levels.

Vref = 1.5 V

Figure 17. Input and Output Voltage Reference Levels for AC Timing Measurements

All rise and fall transition timing parameters are referenced to V

IL

MAX and V

IH

MIN for input clocks, and

V

OL

MAX and V

OH

MIN for output clocks.

Vref = VIL MAX (or VOL MAX)

Vref = VIH MIN (or VOH MIN)

Figure 18. Rise and Fall Transition Time Voltage Reference Levels

Advertising