Telnet console – Moxa Technologies NE-4100 User Manual

Page 33

Advertising
background image

NE-4100 Series User’s Manual

Initial IP Address Configuration

5-3

arp –s 192.168.200.100 00-90-E8-xx-xx-xx

This is where 192.168.200.100 is the new IP address and 00-90-E8-xx-xx-xx is the MAC address
for your NE-4100 Series. You will need to use both numbers, as described above in points 1 and
2.

4. Next, execute a special Telnet command by typing:

telnet 192.168.200.100 6000
After issuing this command, a Connect failed message will
appear, as shown here. After the NE-4100 module reboots, its
IP address should be updated to the new address, and you can
reconnect using Telnet, Web, or Administrator to check that
the update was successful.

Telnet Console

Depending on how your computer and network are configured, you may find it convenient to use
network access to set up your NE-4100 module’s IP address. This can be done using the Telnet
program.

1. From the Windows desktop, click on Start and then select Run.
2. Type telnet 192.168.127.254 (use the

correct IP address if different from the default) in
the Open text input box, and then click OK.



3. Type 2 to select Network settings, and then press Enter.


4. Type 1 to select IP address and then press Enter.

Advertising