Local time

Setting

Factory Default

Necessity

User adjustable time.

GMT (Greenwich Mean Time) Optional

Click on the Modify button to open the Modify time
settings
window to input the correct local time.

Time server

Setting

Factory Default

Necessity

IP or Domain address
(E.g., 192.168.1.1, time.stdtime.gov.tw, or
time.nist.gov)

None Optional

NE-4100 Series uses SNTP (RFC-1769) for auto time calibration.

Input the correct “Time Server” IP address or domain address. Once NE-4100 Series is configured
with the correct Time Server address, NE-4100 Series will request time information from the
“Time Server” every 10 minutes.

Console

The “Disable” option for Web Console and Telnet Console is included for security reasons. In
some cases, you may want to Disable one or both of these Console utilities as an extra precaution
to prevent unauthorized users from accessing your NE-4100 Series. The factory default for both
Web Console and Telnet Console is Enable.

Setting

Factory Default

Necessity

Enable or Disable

Enable

Required

If you disable both the “Web Console” and “Telnet Console,” you can still use the Serial Console to
configure NE-4100 Series locally, or Windows Administrator to configure NE-4100 Series either
locally or remotely over the network.