Moxa Technologies NE-4100 User Manual

Page 83

Advertising
background image

NE-4100 Series User’s Manual

DIO Commands

C-3

C code example:

void WriteSingleDIO(int port, int mode, int status)
{
DIOPacketStruct packet;

packet.header.command = 2; // write single DIO command
packet.header.version = 2; // DIO protocol version
packet.header.length = 3; // data length
packet.data[0] = (char)port; // number of the DIO
packet.data[1] = (char)mode; // DIO mode
packet.data[2] = (char)status; // DIO status;
send(SocketFd, (char *)&packet, sizeof(DIOHeaderStruct)+3, 0); //Send TCP packet
//Process the returned data here
}

3. Reading Multiple DIOs

Parameter:

Command code: 5(hex)

Version: 2(hex)
Command status: doesn’t matter

Length of data: 2(hex); represents two bytes.

data[0]: Number of the DIO you wish to access first.
data[1]: The last number of the DIO you wish to access.

Return:

Command Status : Check the Command Status code on the previous page.

Length

of

data:

(end-start+1)*2

data[0]:

mode

of

start

DIO

data[1]: status of start DIO
data[2]:

mode

of

(start+1)

DIO

data[3]: status of (start+1) DIO
….

data[(end-start)*2]: mode of end DIO

data[(end-start)*2+1]:

status

of

end

DIO

C code example:

BOOL ReadMultipleDIO(int start, int end, int *mode, int *status)
{
DIOPacketStruct packet;

packet.header.command = 5; // Read Multiple DIO Commands
packet.header.version = 2; // DIO protocol command version
packet.header.length = 2; // data length
packet.data[0] = start; // start of the DIO number
packet.data[1] = end; // end of the DIO number
send(SocketFd, (char *)&packet, sizeof(DIOHeaderStruct)+2, 0); //Send TCP packet

//Process the returned data here

return

TRUE;

}

Advertising