SNMP Settings

Community name

Setting

Factory Default

Necessity

1 to 39 characters
(E.g., Support, 886-89191230 #300)

public Optional

A community name is a plain-text password mechanism that is used to weakly authenticate
queries to agents of managed network devices.

Contact

Setting

Factory Default

Necessity

1 to 39 characters
(E.g., Support, 886-89191230 #300)

None Optional

The SNMP contact information usually includes an emergency contact name and telephone or
pager number.

Location

Setting

Factory Default

Necessity

1 to 39 characters
(E.g., Floor 1, office 2)

None Optional

Specify the location string for SNMP agents such as NE-4100 Series. This string is usually set to
the street address where the NE-4100 is physically located.

IP Address Report

When NE-4100 Series products are used in a dynamic IP environment, users must spend more
time with IP management tasks. For example, NE-4100 works as a server (TCP or UDP), and the
host, which acts as a client, must know the IP address of the server. If the DHCP server assigns a
new IP address to the server, the host must take care of what happens when the IP changes.
NE-4100 Series products help out by periodically reporting their IP address to the IP location
server, in case the dynamic IP has changed. The parameters shown below are used to configure
the Auto IP report function. There are two ways to develop an “Auto IP report Server” to receive
NE-4100’s Auto IP report.
1. Use NE-4100 Series Administrator’s IP Address Report function.
2. Refer to Appendix C for the “Auto IP report protocol” to develop your own software.

Auto report to IP

Setting

Factory Default

Necessity

E.g., 192.168.1.1 or URL
(IP addresses of the form x.x.x.0 and
x.x.x.255 are invalid.)

None Optional

Reports generated by the Auto report function will be sent automatically to this IP address.

Auto report to TCP port

Setting

Factory Default

Necessity

E.g., 4001

4002

Optional


Auto report period

Setting

Factory Default

Necessity

Time interval (in seconds)

10

Optional