NE-4100 Series User’s Manual

Web Console Configuration

6-8

Serial Settings

Click on the Serial Settings link on the left side of the screen to display serial settings. Make
necessary changes to the settings and click on submit to validate the modifications.


Port alias

Setting

Factory Default

Necessity

1 to 15 characters
(E.g., PLC-No.1)

None Optional

Port Alias is specially designed to allow easy identification of the serial devices which are
connected to NE-4100 Series’ serial port.

Serial Parameters

Check the serial communication parameters in your Serial Device’s user’s manual. You should set up
NE-4100’s serial parameters with the same communication parameters used by your serial devices.

Baud rate

Setting

Factory Default

Necessity

50 bps to 115.2 Kbps

115.2 Kbps

Required

NE-4100 supports a baud rate setting from 50 bps to 115.2 Kbps.

Data bits

Setting

Factory Default

Necessity

5, 6, 7, 8

8

Required

When the user sets Data bits to 5 bits, the stop bits setting will automatically change to 1.5 bits.

Stop bits

Setting

Factory Default

Necessity

1, 2

1

Required

Stop bits will be set to 1.5 when Data bits is set to 5 bits.

Parity

Setting

Factory Default

Necessity

None, Even, Odd, Space, Mark

None

Required