Mouse – IBM 2274 User Manual

Page 101

Advertising
background image

Check Procedures 67

Mouse

NOTE: A sticking key button can cause the mouse to

operate incorrectly. If you suspect this, go to
“Keyboard” on page 66.

001 - START

•

Make sure that the mouse ball turns freely.

•

Make sure that the mouse plug connects properly.

002 -

•

Power off the system unit.

•

Insert the diagnostics diskette into the diskette
drive.

•

Power on the system unit.

•

Select Interactive Tests menu, then execute
Mouse test.

003 - DO YOU SEE THE MOUSE CURSOR IN THE
DIAGNOSTICS PROGRAM? (YES, READ AHEAD.
NO, GO TO STEP 011)

•

Test right (left) button and check if right (left) button
works.

004 - DOES THE MOUSE BUTTON WORK? (YES,
READ AHEAD. NO, GO TO STEP 007)

•

Test mouse cursor movement.

005 - DOES THE MOUSE MOVE SMOOTHLY AND
KEEP X AND Y COORDINATES CHANGED? (YES,
READ AHEAD. NO, GO TO STEP 006)

•

Mouse is functioned normally.

•

End.

006 -

•

Power off the system unit.

•

Open mouse bottom cover and clean track ball.

•

Go to step 002.

007

•

Power off the system unit.

•

Check the mouse plug.

Advertising