Factory-Installed Modem Card

NOTE: The factory-installed modem is a 56.6 Kbps

modem with a cable of microphone-in and
speaker-out from system board.

001 - START

•

In Windows 98 Device Manager, ensure that the
modem is not configured with a conflicting COM
port and IRQ setting.

•

Ensure that the communication software is
configured with the correct COM and IRQ settings
(same COM port and IRQ as the modem).

•

Ensure that all communication parameters (baud
rate, data, stop and parity bits) are properly
configured and are identical on both sides.

•

Connect the phone line to the LINE port of the
modem card.

•

Power off the system unit.

NOTE: Check the outside phone line by connecting a

working telephone to the telephone wall jack.
Listen for a dial tone to ensure that the phone
line is good.

002 -

•

Insert the diagnostics diskette into the diskette
drive.

•

Power on the system unit.

•

Select Diagnostics menu.

•

Select All Tests, then execute Modem test.

003 - DOES THE MODEM PASS THE TEST? (YES,
READ AHEAD. NO, GO TO STEP 004.)

•

Power off the system unit.

•

Remove all adapter cards.

•

Connect a hard disk drive with pre-loaded
Windows 98.

•

Power on the system unit.

•

Perform the following steps under Windows 98.

NOTE: If an operating system other than Microsoft

Windows 98 is installed, the program screens
and icons may differ from these instructions.