background image

Check Procedures 41

Error Encountered
Initializing Hard Drive

1. Enter Configuration/

Setup Utility to load the
default setting

2. IDE hard disk drive power

3. IDE hard disk drive cable/

connection

4. IDE hard disk drive

Error Initializing Hard Disk
Controller

1. Enter Configuration/

Setup Utility to load the
default setting

2. Check IDE drive jumper

See “3.5-In. Hard Disk
Drive Jumper Settings”
on page 117.

3. IDE hard disk drive power

4. IDE hard disk drive cable/

connection

5. IDE hard disk drive

6. System board

Floppy Disk CNTRLR Error
Or No CNTRLR Present

1. Enter Configuration/

Setup Utility to load the
default setting

2. Diskette drive cable/

connection

3. Diskette drive

4. System board

Invalid EISA Configuration

Please Run EISA
Configuration Utility

1. No ESIA slot available

Keyboard Error or No
Keyboard Present

1. Re-connect keyboard

2. Enter Configuration/

Setup Utility and load the
default settings

3. keyboard

4. System board

Table 2-1 POST Error Codes and Messages List

NOTE:

To diagnose a problem, first find the BIOS error

messages or codes in left column. If directed to a
check procedure, replace the FRU indicated in the
check procedure. If no check procedure is indicated,
the first Action/FRU listed in right column is the most
likely cause.